AFX Series
Precision Air Conditioning
This manual provides information for installation, operation and preventive
maintenance. The user should observe the guidelines and procedures presented herein
to promote satisfactory performance. Due to an ongoing program dedicated to product
improvement, specifications are subject to revision without notice. APC assumes no
responsibility, and disclaims all liability for damages resulting from use of this
information or for any errors or omissions.
American Power Conversion
132 Fairgrounds Road
West Kingston, RI 02892
Telephone: 800-800-4APC
Website: www.apc.com
OPERATION AND MAINTENANCE
MANUAL
February 10, 2003
Page view 0
1 2 3 4 5 6 ... 22 23

Summary of Contents

Page 1 - AFX Series

AFX Series Precision Air Conditioning This manual provides information for installation, operation and preventive maintenance. The

Page 2 - Table of Contents

9 Installation (continued) Drycooler and Pump Package Connection Provide sufficient valves and unions to isolate the dry cooler and pump package

Page 3 - The AFX Series

10 Piping Connections Refrigerant Pipe Connections; AIR-COOLED When piping air-cooled systems, care must be taken to use only clean refrigerant gr

Page 4 - Standard Features

11 Pre Start-Up Prior to initial start-up, perform the following checks to ensure proper unit operation: ELECTRICAL CHECKS 1. Check to make sure t

Page 5 - Optional Equipment

12 Charging the System The AFX Series Water/Glycol and the integral mounted Air-cooled systems are factory charged with refrigerant. All other dir

Page 6

13 Control/Safety Adjustments After the installation and start-up of the AFX Series unit has been completed, "fine tuning" of the system&

Page 7 - Installation

14 Control/Safety Adjustments OVERLOAD RELAY The blower motor starter has an adjustable overload relay. The adjustment dial should be set to cor

Page 8

15 Humidifier Operation Your AFX Series unit may be equipped with a pure steam generator type humidifier as an option. Check all electrical connect

Page 9

16 Troubleshooting PROBLEM Controls erratic or inoperative Evaporator coil ices Blower fails to start Compressor fail

Page 10 - Installation (continued)

17 Troubleshooting PROBLEM Compressor short cycles. Noisy compressor. System short of capacity.

Page 11 - Piping Connections

18 Troubleshooting PROBLEM Head pressure too high. Head pressure too low. Suction pressure too low.

Page 12 - Start-Up

Introduction Congratulations on the selection of an APC environmental control system. The unit incorporates the latest system design innovati

Page 13 - System Function

19 Troubleshooting PROBLEM Humidifier inoperative. Reheat elements inoperative. Water carryover. Controller fails to

Page 14 - Control/Safety Adjustments

20 Preventive Maintenance The operating life of the AFX Series system can be extended by following a simple preventive maintenance schedule. The s

Page 15

21 Warranty The limited warranty provided by American Power Conversion Corporation ("APC") in this Statement of Limited Factory Warranty a

Page 17 - Troubleshooting

The AFX Series The APC AFX series precision air-conditioning system provides compact, quiet, efficient, and reliable system solutions in the expandi

Page 18

3 Standard Features Overall cabinet The frame is constructed of heavy gauge steel for maximum strength. The unit has been designed for full service

Page 19

Optional Equipment Smoke detector(s) A factory installed smoke detector is designed to sense smoke concentration in the return air stream. Upon det

Page 20

5 Optional Equipment (continued) Environmental monitoring unit A stand-alone unit performs continuous temperature and humidity sensing through t

Page 21 - Preventive Maintenance

6 Installation Computer Room Preparation During the design of the computer room, consideration should be given to the following factors: ease of en

Page 22 - Warranty

7 Installation (continued) UPFLOW DISCHARGE In data processing facilities designed for upflow discharge systems, air distribution is either through

Page 23

8 Installation (continued) Power Connection The AFX unit uses three phase power for operation. Bring the service cable through the 3/4" bulk