APC NetworkAIR™ AFX 1
Overview
The APC NetworkAIR AFX com-
puter room air conditioning system
provides a quiet, efficient, and reli-
able solution for heat sensitive
equipment areas.
Precision environmental require-
ments now reach far beyond the
confines of the traditional data cen-
ter or computer room to encompass
a larger suite of applications,
referred to as technology rooms.
Critical environment applications
include:
Computer rooms
Telecommunication facilities
Clean rooms
Power equipment
Medical equipment rooms
Archives
LAN/WAN environments
A worldwide network of APC rep-
resentatives is fully qualified to
provide engineering, sales, installa-
tion and service for our products.
APC warrants all parts for 12
months from shipment. Extended
warranties are available.
Models
AFX is available in two models:
AFX18, AFX65.
Room Air Distribution
Downflow systems discharge air
into the raised floor plenum. These
systems are suitable for areas with
raised floors greater than 12" (305
mm) high. Return air is drawn in
through the top of the system.
Upflow systems discharge air into
either a plenum or ductwork. These
systems are suitable for areas with-
out raised floors, as well as areas
with raised floors. Air is drawn in
through the front of the system.
Configuration
Glycol Cooled
Water Cooled
Air Cooled
Compliance Approval
ETL/CETL
UL Listed to UL 1995 and CSA
C22.2 No. 236
MEA #223-99-E (City of New
Yor k)
Standard Features
Scroll Compressor(s)
Centrifugal Blower Assembly
Heavy Gauge Steel Frame
Main Power Circuit Breaker
Microprocessor Controller
Bearing Life, L
10
- 200,000 hrs
Front Service Access Only
Pure Steam Canister Humidifier
30% ASHRAE 52.1 Filters
Three Phase Electric Reheat
Environmental Monitoring
Redundant Group Control
Condensate Pump
Optional Features
2 or 3 Way Fluid Regulating
Valves (Water or Glycol)
Brazed Plate Condenser (Water or
Glycol)
Plenums (with or without grilles)
Floorstand (with or without air
deflectors, seismic)
Discharge Duct Collar
Downflow Return Duct
ModBus/JBus Gateway
OHE Disconnect
Spot or Cable Water Detector(s)
•Firestat
Smoke Detector
Remote Relay Shutdown
Reheat/Humidity or Compressor
Lockout
Remote Display and/or Sensor
Hot Gas Bypass
Secondary Drain Pan
3-Way Valve Flowswitch
Custom Alarm Contacts
CUS