WINTER / SPRING 2005 SOLUTIONS.APC.COM 13
Before: Using traditional cooling methods, the
heat generated in IT racks circulates throughout
the room. This results in the mixing of hot and
cold air, preventing efficient cooling of high-
density areas.
After: Innovative InfraStruXure
technology
utilizes a self-contained cooling system that
doesn’t require cooling of the entire room. This
technology neutralizes hot air where it is
created, resulting in the ability to cool up to
20kW in any rack.
TRADITIONAL COOLING METHODS VS. APC’S INNOVATIVE
SELF-CONTAINED COOLING
12 SOLUTIONS.APC.COM WINTER / SPRING 2005
ACPA4000
Portable, self-contained air conditioning
solutions for small rooms and data closets
4kW 120V 60Hz
Cooling capacity options - 3.90 kW, 13,306
BTUs
Air Flow - 600.00 CFM
Automatic restart
Reduce downtime
Starting at $4,225
CM-DX, CM-CW
Ceiling-mount precision air conditioning
Cooling capacity options - 1, 1.5, 2, 3, 4, 5 tons;
3, 5, 7, 10, 14, 17 kW
Cooling options - air, water, glycol, chilled water
Humidification value - 5 lbs/hour
Standard warranty - 1 year parts
Call for pricing*
NetworkAIR
PA NetworkAIR
CM
NetworkAIR
CW
CCT-CW
Floor mount precision air conditioning using
chilled water
Cooling capacity options - 6, 8, 12, 15, 20, 25, 30,
35, 40, 50, 60 tons ; 20, 27, 41, 50, 70, 87, 105, 123,
140, 175, 210 kW
Cooling options - chilled water
Humidification value - 5, 17 lbs/hour
Standard warranty - 1 year parts
Call for pricing*
“We decided to
purchase the APC
NetworkAIR
to
handle our precision
air requirements. The
NetworkAIR units are
high quality. Compared
to some of APC’s
precision air
competitors, the APC
NetworkAIR costs
less and has a much
faster delivery time. In
addition, it was much
easier for us to deal
with one vendor to
integrate the data
center solution and we
felt we would get better
support from APC.
“We figure that our
consolidation project
has contributed
significantly to our cost
reduction efforts. APC
InfraStruXure
and
NetworkAIR are key
components which
have helped us to
realize these savings.”
Evan Stewart, CIO
Sam Villegas,
Partner Relations,
BE Aerospace
Order online at APC’s Store:
solutions.apc.com
Or order by phone:
1-888-289-APCC x3320
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Portable cooling
for IT applications
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Mounts above
the ceiling
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Controls
temperature
and humidity
using chilled
water
Cooling
SOLUTIONS
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Rack Air Distribution Unit
ACF001
120V 60Hz
Air distribution for power dense enclosures
and low pressure areas
Adjustable design
Air filtration
Dual A-B power inputs
Improves air circulation
Minimizes air mixing
Promotes proper airflow
Starting at $729
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Distributes
conditioned air
directly into the
enclosure
ACF201BLK
120V 60Hz
Adjustable design
Dual A-B power inputs
Improves air circulation
Minimizes air mixing
Starting at $559
Rack Side Air Distribution Unit
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Air distribution
with side-to-
side airflow
ACF101BLK*
120V 60Hz
Dual A-B power inputs
Ducted exhaust system
Power or temperature controlled fans
Redundant fans
Zero U solution
Starting at $2,475
Rack Air Removal Unit
.
..
...
....
.....
......
.......
........
.......
......
.....
....
...
..
.
Heat removal
for high density
enclosures
*Rack not included
These simulations show IT enclosures in a data center environment, arranged in a hot aisle/cold
aisle format, where rack fronts face other rack fronts, and rack backs face other rack backs.
Call to order 1-888-289-APCC x3320
Shop online 24 hours a day, 7 days a week at http://solutions.apc.com
*units are assembled-to-order