APC PDPB150G6F User's Guide

Browse online or download User's Guide for Distribution power transformers APC PDPB150G6F. APC PDPB150G6F User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 116
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - User Guide

User GuideInfraStruxure 150kVAPower Distribution UnitPDPB150G6F

Page 2

User Guide InfraStruxure 150kVA Power Distribution Unit 2Network management featuresThese applications and utilities work with a PDU that connects to

Page 3 - Contents

User Guide InfraStruxure 150kVA Power Distribution Unit 92Set the Date and TimePath: Administration > General > Date & Time > modeSet the

Page 4

93User Guide InfraStruxure 150kVA Power Distribution Unit Use an .ini File Path: Administration > General > User Config FileUse the settings fro

Page 5

User Guide InfraStruxure 150kVA Power Distribution Unit 94To reconfigure any of the following, click the link name in the Display column:• Display: Th

Page 6

95User Guide InfraStruxure 150kVA Power Distribution Unit APC Device IP Configuration WizardCapabilities, Requirements, and InstallationHow to use the

Page 7

User Guide InfraStruxure 150kVA Power Distribution Unit 96Use the WizardNote: Most software firewalls must be temporarily disabled for the Wizard to d

Page 8

97User Guide InfraStruxure 150kVA Power Distribution Unit Configure or reconfigure the TCP/IP settings locally1. Contact your network administrator to

Page 9 - Introduction

User Guide InfraStruxure 150kVA Power Distribution Unit 98Export Configuration SettingsRetrieve and Export the .ini FileSummary of the procedureAn Adm

Page 10 - Internal Management Features

99User Guide InfraStruxure 150kVA Power Distribution Unit Customizing. You must customize the file before you export it.1. Use a text editor to custom

Page 11

The Upload Event and Error MessagesThe event and its error messagesThe following event occurs when the receiving PDU completes using the .ini file to

Page 12 - Watchdog Features

101User Guide InfraStruxure 150kVA Power Distribution Unit File TransfersUpgrading FirmwareBenefits of upgrading firmwareWhen you upgrade the firmware

Page 13 - Command Console

3User Guide InfraStruxure 150kVA Power Distribution Unit • A Read-Only User has the following restricted access:– Access through the Web interface on

Page 14 - Main Screen

User Guide InfraStruxure 150kVA Power Distribution Unit 102Firmware File Transfer MethodsTo upgrade the firmware of a PDU, use one of these methods:•

Page 15 - Command errors

103User Guide InfraStruxure 150kVA Power Distribution Unit 6. When FTP confirms the transfer, type quit to close the session.7. After 20 seconds, repe

Page 16 - Login timeout and lockout

Use XMODEM to upgrade one PDUTo upgrade the firmware for one PDU that is not on the network, you must extract the firmware files from the firmware upg

Page 17 - Command syntax

105User Guide InfraStruxure 150kVA Power Distribution Unit Verifying Upgrades and Updates Verify the success or failure of the transferTo verify wheth

Page 20 - ? or help

10/2012990-4414APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of the following ways

Page 21 - Administrator, Device

User Guide InfraStruxure 150kVA Power Distribution Unit 4Watchdog FeaturesOverviewTo detect internal problems and recover from unanticipated inputs, t

Page 22 - Option Arguments Description

5User Guide InfraStruxure 150kVA Power Distribution Unit Command Console OverviewOverviewUse either a local (serial) connection, or a remote (Telnet o

Page 23 - Example:

User Guide InfraStruxure 150kVA Power Distribution Unit 6Local access to the command line interfaceFor local access, use a computer that connects to t

Page 24

7User Guide InfraStruxure 150kVA Power Distribution Unit • The User field reports whether you logged in through the Administrator or Device Manager ac

Page 25

User Guide InfraStruxure 150kVA Power Distribution Unit 8OptionsThe command line interface provides options to configure the network settings and mana

Page 26 - Administrator

9User Guide InfraStruxure 150kVA Power Distribution Unit Command syntaxArgument Quoting. Argument values may optionally be enclosed in double quote ch

Page 27 - Key Description

User Guide InfraStruxure 150kVA Power Distribution Unit 10Syntax examples<command> <arg1> [<agr2> <arg3a | arg3b> [<arg4a |

Page 28

11User Guide InfraStruxure 150kVA Power Distribution Unit Command Response CodesThe command line interface reports all command operations with the fol

Page 30 - Option Argument Description

User Guide InfraStruxure 150kVA Power Distribution Unit 12Interface Management Commands ? or helpAccess: Administrator, Device Description: View a lis

Page 31 - Examples:

13User Guide InfraStruxure 150kVA Power Distribution Unit aboutAccess: Administrator, Device Description: View hardware and firmware information (Mode

Page 32

User Guide InfraStruxure 150kVA Power Distribution Unit 14alarmcountAccess: Administrator, Device Description: Display the count alarms that are prese

Page 33

15User Guide InfraStruxure 150kVA Power Distribution Unit bootAccess: Administrator onlyDescription: Allows the user to get/set the network startup co

Page 34

User Guide InfraStruxure 150kVA Power Distribution Unit 16cdAccess: Administrator, Device UserDescription: Allow the user to set the working directory

Page 35

17User Guide InfraStruxure 150kVA Power Distribution Unit dateAccess: Administrator onlyDefinition: Set the date and time. Example 1: To display the

Page 36 - Administrator only

User Guide InfraStruxure 150kVA Power Distribution Unit 18dirAccess: Administrator, Device Description: Display the files and folders stored in the w

Page 37 - Device Management Commands

19User Guide InfraStruxure 150kVA Power Distribution Unit eventlogAccess: Administrator, Device UserDescription: View the date and time you retrieved

Page 38 - Panels & Subfeed

User Guide InfraStruxure 150kVA Power Distribution Unit 20exit or quit Access: Administrator, Device UserDescription: Exit/Quit/ Leave the command lin

Page 39 - Input Contacts

21User Guide InfraStruxure 150kVA Power Distribution Unit pingAccess: Administrator, Device Description. Determine whether the device with the IP add

Page 40 - Output Relays

ContentsUserGuide InfraStruxure 150kVA Power Distribution Unit iIntroduction... 1Pro

Page 41

User Guide InfraStruxure 150kVA Power Distribution Unit 22promptAccess: Administrator, Device UserDescription: Allow the user to change the format of

Page 42

23User Guide InfraStruxure 150kVA Power Distribution Unit radiusAccess: Administrator onlyDescription: View the existing RADIUS settings, enable or di

Page 43

User Guide InfraStruxure 150kVA Power Distribution Unit 24rebootAccess: Administrator onlyDescription: Restart the interface of the PDU. Confirm the o

Page 44 - Enable

25User Guide InfraStruxure 150kVA Power Distribution Unit systemAccess: Administrator onlyDescription: View and set the system name, contact, and loca

Page 45

User Guide InfraStruxure 150kVA Power Distribution Unit 26tcpip6Access: Administrator onlyDescription: Enable IPv6 and view and manually configure the

Page 46

27User Guide InfraStruxure 150kVA Power Distribution Unit webAccess: AdministratorDescription: Enable access to the Web interface using HTTP or HTTPS.

Page 47

User Guide InfraStruxure 150kVA Power Distribution Unit 28xferStatusAccess: Administrator onlyDescription: View the result of the last INI file trans

Page 48

29User Guide InfraStruxure 150kVA Power Distribution Unit Device Management CommandsMany device management commands are settable and will accept data

Page 49

User Guide InfraStruxure 150kVA Power Distribution Unit 30Panels & SubfeedPower distribution is accomplished through two breaker panels and one su

Page 50

31User Guide InfraStruxure 150kVA Power Distribution Unit Breakers & CablesEach breaker and associated cables can be queried for status, configure

Page 51

UserGuide InfraStruxure 150kVA Power Distribution UnitiiInterface Management Commands. . . . . . . . . . . . . . . . . . . . . . . . . . 12? or help

Page 52

User Guide InfraStruxure 150kVA Power Distribution Unit 32Output RelaysThe output relays provide a means to generate an external signal based on prede

Page 53

33User Guide InfraStruxure 150kVA Power Distribution Unit sysOutputAccess: Administrator, Device Description: View each phase-to-phase voltage, each

Page 54

User Guide InfraStruxure 150kVA Power Distribution Unit 34sysThrMxVAccess: Administrator, Device Description: Configure the maximum voltage (L-N) ala

Page 55

35User Guide InfraStruxure 150kVA Power Distribution Unit sysThrMnVAccess: Administrator, Device Description: Configure the minimum voltage (L-N) ala

Page 56

User Guide InfraStruxure 150kVA Power Distribution Unit 36sysThrLoIAccess: Administrator, Device Description: Configure the low current alarm thresho

Page 57 - Example

37User Guide InfraStruxure 150kVA Power Distribution Unit subfdStatusAccess: Administrator, Device Description: If no parameter is entered, the statu

Page 58

User Guide InfraStruxure 150kVA Power Distribution Unit 38subfdLocAccess: Administrator, Device Description: Configure the location of the targeted s

Page 59

39User Guide InfraStruxure 150kVA Power Distribution Unit subfdThrMxAccess: Administrator, Device Description: Configure the maximum load alarm thres

Page 60

User Guide InfraStruxure 150kVA Power Distribution Unit 40subfdThrLoAccess: Administrator, Device Description: Configure the low load alarm threshold

Page 61

41User Guide InfraStruxure 150kVA Power Distribution Unit subfdBrkrAccess: Administrator, Device Description: Configure the breaker position critical

Page 62

UserGuide InfraStruxure 150kVA Power Distribution Unit iiiDevice Management Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . .29System .

Page 63

User Guide InfraStruxure 150kVA Power Distribution Unit 42brkrPanelAccess: Administrator, Device Description. Select the panel containing the breaker

Page 64

43User Guide InfraStruxure 150kVA Power Distribution Unit Example: apc>brkrStatus1. 1.1,pb1-1,Unknown,,20A,50A,Normal,0.0kW,1.7kWh,08/01/20122. 1.

Page 65

User Guide InfraStruxure 150kVA Power Distribution Unit 44brkrNameAccess: Administrator, Device Description. Configure the name on the breaker select

Page 66

45User Guide InfraStruxure 150kVA Power Distribution Unit brkrAlrmAccess: Administrator, Device Description. Enables alarm generation on the cable br

Page 67

User Guide InfraStruxure 150kVA Power Distribution Unit 46brkrThrMxAccess: Administrator, Device Description. Configure the max load alarm threshold

Page 68 - Web Interface

47User Guide InfraStruxure 150kVA Power Distribution Unit brkrThrLoAccess: Administrator, Device Description. Configure the low load alarm threshold

Page 69 - URL address formats

User Guide InfraStruxure 150kVA Power Distribution Unit 48brkrRstkWhAccess: Administrator, Device Description. Reset the usage and usage date on the

Page 70 - Home Page

49User Guide InfraStruxure 150kVA Power Distribution Unit brkrAddAccess: Administrator, Device Description. Add a breaker at the panel position selec

Page 71

User Guide InfraStruxure 150kVA Power Distribution Unit 50mfactMeterAccess: Administrator, Device Description: Displays model number, serial number,

Page 72 - Quick Links

51User Guide InfraStruxure 150kVA Power Distribution Unit 10. 8-50,9-50,10-50,11-50,12-50,13-50,14-50,11. 15-50,16-50,17-50,18-50,19-50,20-50,21-50,12

Page 73 - The Power Distribution Tab

UserGuide InfraStruxure 150kVA Power Distribution UnitivicTarget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 74

User Guide InfraStruxure 150kVA Power Distribution Unit 52mfactkWhsAccess: Administrator, Device Description: Reads and displays two panels of the en

Page 75 - The Environment Tab

53User Guide InfraStruxure 150kVA Power Distribution Unit icStatusAccess: Administrator, Device Description: Display input contact, alarm status, ala

Page 76 - Event and Data Logs

User Guide InfraStruxure 150kVA Power Distribution Unit 54icLocAccess: Administrator, Device Description: Configure the location of the targeted inpu

Page 77 - Data log

55User Guide InfraStruxure 150kVA Power Distribution Unit icAlarmAccess: Administrator, Device Description: Enable/disable alarm of the targeted inpu

Page 78

User Guide InfraStruxure 150kVA Power Distribution Unit 56orStatusAccess: Administrator, Device Description: Display the output relay name and the st

Page 79

57User Guide InfraStruxure 150kVA Power Distribution Unit orNormalAccess: Administrator, Device Description: Configure the normal state of the target

Page 80 - Administration: Security

User Guide InfraStruxure 150kVA Power Distribution Unit 58orSubxxxxAccess: Administrator, Device Description: This category of alarm mapping commands

Page 81 - RADIUS

59User Guide InfraStruxure 150kVA Power Distribution Unit Parameters: [<relay> <enable|disable>]relay = output relay to be triggered(norma

Page 82 - Inactivity Timeout

User Guide InfraStruxure 150kVA Power Distribution Unit 60Web InterfaceIntroductionSupported Web browsersYou can use Microsoft® Internet Explorer (IE)

Page 83 - TCP/IP Settings

61User Guide InfraStruxure 150kVA Power Distribution Unit URL address formatsType the DNS name or IP address of the PDU in the URL address field of th

Page 84 - Setting Description

UserGuide InfraStruxure 150kVA Power Distribution Unit vAdministration: Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Page 85 - DHCP response options

User Guide InfraStruxure 150kVA Power Distribution Unit 62Home PageOverviewOn the Home tab, displayed when you log on to the Web interface, you can vi

Page 86 - Port Speed

63User Guide InfraStruxure 150kVA Power Distribution Unit How to Use the Tabs, Menus, and LinksTabsIn addition to the tab for the Home page, the follo

Page 87

User Guide InfraStruxure 150kVA Power Distribution Unit 64MenusLeft navigation menu. Each tab (except the tab for the home page) has a left navigation

Page 88 - Option Description

65User Guide InfraStruxure 150kVA Power Distribution Unit The Power Distribution TabAccess detailed PDU status informationPath: Power Distribution >

Page 89 - Console

User Guide InfraStruxure 150kVA Power Distribution Unit 66View and edit branch circuit breaker settingsPath: Power Distribution > Panel # > even

Page 90 - SNMPv1

67User Guide InfraStruxure 150kVA Power Distribution Unit The Environment TabView and configure input contact settingsPath: Environment > Input Con

Page 91 - SNMPv3

User Guide InfraStruxure 150kVA Power Distribution Unit 68Event and Data LogsEvent log Path: Logs > Events You can view, filter, or delete the even

Page 92 - FTP Server

69User Guide InfraStruxure 150kVA Power Distribution Unit To configure reverse lookup (Logs > Events > reverse lookup): Reverse lookup is disabl

Page 93 - Administration: Notification

User Guide InfraStruxure 150kVA Power Distribution Unit 70To set the data collection interval (Logs > Data > interval): Define, in the Log Inter

Page 94 - Configure event actions

71User Guide InfraStruxure 150kVA Power Distribution Unit Using FTP or SCP to retrieve log filesAn Administrator or Device User can use FTP or SCP to

Page 95 - E-mail notification

UserGuide InfraStruxure 150kVA Power Distribution UnitviExport Configuration Settings ...98Retrieve and Export the .

Page 96 - E-mail recipients

User Guide InfraStruxure 150kVA Power Distribution Unit 723. Use the get command to transmit the text of a log to your local drive.ftp>get event.tx

Page 97 - SNMP traps

73User Guide InfraStruxure 150kVA Power Distribution Unit APC supports the authentication and authorization functions of RADIUS (Remote Authentication

Page 98 - Syslog Settings

User Guide InfraStruxure 150kVA Power Distribution Unit 74Configure the RADIUS Server. You must configure your RADIUS server to work with the PDU.For

Page 99 - Identification

75User Guide InfraStruxure 150kVA Power Distribution Unit Administration: Network FeaturesPath: Administration > NetworkTCP/IP SettingsPath: Admini

Page 100 - Daylight saving

User Guide InfraStruxure 150kVA Power Distribution Unit 76Setting DescriptionManual The IP address, subnet mask, and default gateway must be configure

Page 101 - Configuring Links

77User Guide InfraStruxure 150kVA Power Distribution Unit DHCP response optionsEach valid DHCP response contains options that provide the TCP/IP setti

Page 102 - About the PDU

User Guide InfraStruxure 150kVA Power Distribution Unit 78Other options. The PDU also uses these options within a valid DHCP response. All of these op

Page 103 - Installation

79User Guide InfraStruxure 150kVA Power Distribution Unit • Select naming to define the host name and domain name of the PDU:– Host Name: After you c

Page 104 - Use the Wizard

User Guide InfraStruxure 150kVA Power Distribution Unit 80WebPath: Administration > Network > Web > optionsOption Descriptionaccess To activa

Page 105

81User Guide InfraStruxure 150kVA Power Distribution Unit Console Path: Administration > Network > Console > optionsNote: To use SSH, you mus

Page 106 - Export Configuration Settings

1User Guide InfraStruxure 150kVA Power Distribution Unit IntroductionProduct FeaturesThe Network Management Card (NMC) in your Power Distribution Unit

Page 107

User Guide InfraStruxure 150kVA Power Distribution Unit 82SNMPSNMPv1. Path: Administration > Network > SNMPv1 > optionsAll user names, passwo

Page 108 - Related Topics

83User Guide InfraStruxure 150kVA Power Distribution Unit SNMPv3. Path: Administration > Network > SNMPv3 > optionsFor SNMP GETs, SETs, and t

Page 109 - File Transfers

User Guide InfraStruxure 150kVA Power Distribution Unit 84FTP Server Path: Administration > Network > FTP ServerThe FTP server settings enable (

Page 110

85User Guide InfraStruxure 150kVA Power Distribution Unit Administration: NotificationPath: Administration > NotificationEvent Actions Path: Admini

Page 111 - How to upgrade multiple PDUs

User Guide InfraStruxure 150kVA Power Distribution Unit 86Configure event actionsNotification Parameters. For events that have an associated clearing

Page 112 - Use XMODEM to upgrade one PDU

87User Guide InfraStruxure 150kVA Power Distribution Unit E-mail notificationOverview of setup. Use the Simple Mail Transfer Protocol (SMTP) to send e

Page 113 - Last Transfer Result codes

User Guide InfraStruxure 150kVA Power Distribution Unit 88SMTP. Path: Administration > Notification > E-mail > serverE-mail recipients. Path:

Page 114

89User Guide InfraStruxure 150kVA Power Distribution Unit SNMP trapsTrap Receivers. Path: Administration > Notification > SNMP Traps > trap r

Page 115

User Guide InfraStruxure 150kVA Power Distribution Unit 90SyslogPath: Logs > Syslog > optionsThe PDU can send messages to up to four Syslog serv

Page 116 - 10/2012990-4414

91User Guide InfraStruxure 150kVA Power Distribution Unit Syslog Test and Format example. Path: Logs > Syslog > testSend a test message to the S

Comments to this Manuals