APC SYMMETRA 990 User's Guide

Browse online or download User's Guide for Network switches APC SYMMETRA 990. APC SYMMETRA 990 User`s guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Operation

OperationSymmetra® PX10-40 kW400 V and 208 V

Page 2

Overview – Display Interface4 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001StatuStatus screensThe status screens display information re

Page 3 - About this Manual

Overview – Display Interface990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 5Setup screensFrom the setup screen, the default factory sett

Page 4

Overview – Display Interface6 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001Accessories screenFrom the accessories screen, you can view

Page 5 - Contents

Overview – Display Interface990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 7Display screenThe display screen allows you to customize the

Page 6

Overview – Display Interface8 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001Diags screensThe diagnostics screen provides information use

Page 7

990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 9OperationOperation ProceduresHow to perform a total power off Caution: To ensure the uni

Page 8 - Overview

Operation – Operation Procedures10 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001How to turn load ON/OFF1. Select Control on the top-lev

Page 9 - Control screen

Operation – Operation Procedures990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 11Note: The H2 LED above the Q2 Breaker should then illum

Page 10 - Status screens

Operation – Operation Procedures12 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-0012. Set the Symmetra PX UPS DC disconnect breaker and th

Page 11 - Setup screens

Operation – Operation Procedures990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 13Note: The H2 LED above the Q2 breaker should then illum

Page 13 - Display screen

14 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001System Re-Start (if applicable)Warning: Only APC-trained personnel familiar with the co

Page 14 - Help screens

Operation – System Re-Start (if applicable)990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 15Note: Wait approximately 30 seconds for syst

Page 15

16 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001Communication Configuration Network connection/APC Web Management CardNote: The network

Page 16 - How to turn load ON/OFF

990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 17Quick configurationNote: Disregard the procedures in this section if your system includ

Page 17

18 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001MaintenanceParts ReplacementHow to obtain replacement modulesTo obtain a replacement mo

Page 18 - Top-level menu

Maintenance – Parts Replacement990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 19How to replace the power modulesWarning: Only trained pe

Page 19 - Confirmation screen

Maintenance – Parts Replacement20 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001How to replace the batteriesHeavy: Two people are requir

Page 20 - How to re-start the system

Maintenance – Parts Replacement990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 21Note: When installing the batteries, start from the lowe

Page 21

22 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001Troubleshooting This section lists all of the common alarm and status messages that mig

Page 22 - Communication Configuration

Troubleshooting – Parts Replacement990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 23# Pwr modules changed since last ONAt least one powe

Page 23 - Quick configuration

990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V OperationAbout this ManualThis manual is intended for the users of the Symmetra® PX 10-40 kW UPS.Co

Page 24 - Part 400V 208V

Troubleshooting – Parts Replacement24 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001General faultExternal switch gear Q002 openedThe ext

Page 25

Troubleshooting – Parts Replacement990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 25No Batteries Are ConnectedNo battery power is availa

Page 26 - How to replace the batteries

Troubleshooting – Parts Replacement26 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001Module failureThreshold alarmSwitch Gear Communicati

Page 27 - How to replace cards

Troubleshooting – Parts Replacement990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 27BypassRedundancy Is Below Alarm LimitActual power mo

Page 28 - Troubleshooting

Troubleshooting – Parts Replacement28 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001If the system works in bypass, ensure the presence o

Page 30 - General fault

08/2008990-4147D-001*990-4147D-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any o

Page 32 - Threshold alarm

Contents990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation iSafety...

Page 33

ii Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001Maintenance... 18Parts

Page 34 - Support

990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 1SafetyWarning: ALL safety instructions in the Safety Sheet (990-2984) shall be read, und

Page 35

2 Symmetra PX 10-40 kW 400 V and 208 V Operation 990-4147D-001OverviewDisplay InterfaceOverviewThe display is the UPS user interface. It is used to co

Page 36 - *990-4147D-001*

990-4147D-001 Symmetra PX 10-40 kW 400 V and 208 V Operation 3Top-level menu screenWhen the top-level status screen is active, press ENTER to open th

Comments to this Manuals

No comments