OperationSmart-UPS® VT ISX20-30 kVA208/480 V

Page 2

6 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819NavigationThe menu tree provides a quick overview of the user interface functions.The m

Page 3 - Contents

UPS Overview – Navigation990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 7Basic display navigation principlesOn the display, press ESC u

Page 4

UPS Overview – Navigation8 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Switch load OFF (disconnect the UPS output to the load equipme

Page 5 - Introduction

UPS Overview – Navigation990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 9Frequencies. Utility frequency, bypass frequency and output fr

Page 6 - UPS Overview

UPS Overview – Navigation10 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Time• To change the time, press ENTER (the hour field will be

Page 7 - User Interface

UPS Overview – Navigation990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 11View Statistics (submenu under Logging). From the Logging scr

Page 8 - Temperature Sensor

UPS Overview – Navigation12 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819To change the language, select Language, and press ENTER. The

Page 9 - The Display

UPS Overview – Navigation990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 13• From the Main Menu, select Diags, and press ENTER• Use UP/D

Page 10

14 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Operation ModesIn a stand-alone installation, the UPS has four different operating mod

Page 11 - Control functions

UPS Overview – Operation Modes990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 15Turn into mechanical bypass using the Mechanical Bypass

Page 13 - Clock set-up

UPS Overview – Operation Modes16 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Turn into normal operation (from mechanical bypass opera

Page 14 - Logging Screen

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 17Restart ProcedurePower application Set the utility breaker to the ON position.If you

Page 15 - Display setup

UPS Overview – Restart Procedure18 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Voltage confirmation At the restart, the display will

Page 16 - Diagnostics screen

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 19Load ConnectionAt the rear, the UPS contains at least one Distribution Units (PDU). As

Page 17

Load Connection – Restart Procedure20 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Set the applicable breaker to the OFF position (ma

Page 18 - Operation Modes

Load Connection – Restart Procedure990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 21PDU output breaker ratingsNominal rating of breaker

Page 19

22 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Maintenance Battery ReplacementBattery ModulesOne Battery Module consists of 4 Battery

Page 20

Maintenance – Battery Replacement990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 23Holding the battery handle, gently push the battery

Page 21 - Restart Procedure

Maintenance – Battery Replacement24 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Install batteries in the lowest available bay. Posi

Page 22 - Voltage confirmation

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 25Network Management Card ReplacementLoosen the 2 torx screws (one each side of the car

Page 23 - Load Connection

Contents990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation iIntroduction...1UPS O

Page 24

26 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819How to Obtain Orderable PartsTo obtain a orderable part, contact APC Customer Support

Page 25 - PDU output breaker ratings

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 27TroubleshootingThis section lists the status and alarm messages that the UPS might dis

Page 26 - Maintenance

Troubleshooting – How to Obtain Orderable Parts28 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Load Is No Longer Above Alarm Threshold

Page 27 - Battery Module Installation

Troubleshooting – How to Obtain Orderable Parts990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 29If a problem persists, note UPS model #

Page 28 - BATTERY UNIT

01/2006990-2819*990-2819*Customer support for this or any other APC product is available at no charge in any of the following ways:• Visit the APC Web

Page 29 - Reattach the two torx screws

– ii Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819Maintenance ... 22Battery Rep

Page 30 - How to Obtain Orderable Parts

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 1IntroductionWelcome to the Operation manual covering the Smart-UPS® VT ISX. This manual

Page 31 - Troubleshooting

2 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819UPS Overview10/100Base-TProbeAP9619 Network Management Card EM!ResetOutputPwrZone10/100

Page 32

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 3User Interface The UPS has a lock mechanism on the front and rear panels. The key is pr

Page 33

UPS Overview – User Interface4 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 990-2819APC Network Management Card AP9619 (installed in UPS) with

Page 34 - *990-2819*

990-2819 Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 5The DisplayThe four LEDs to the left of the display indicate the operational status of