®®®®USER’S GUIDEmasterswitch vmProduct DescriptionsProducts Described in This ManualMasterSwitch VM PDUsAPC provides three MasterSwitch VM PDUs:•AP922
®®®®USER’S GUIDEmasterswitch vmSet-up. Com2Telnet requires Java Runtime Environment (JRE), version 1.3 or higher.1. To check your version of JRE, use
®®®®USER’S GUIDEmasterswitch vmLaunching Com2TelnetTo enable remote monitoring of your MasterSwitch VM unit:1. Log on to the computer on which you ins
®®®®USER’S GUIDEmasterswitch vmReprogram Firmware option (not for use remotely)The Com2Telnet program uses the firmware of the MasterSwitch VM unit it
®®®®USER’S GUIDEmasterswitch vmInitial setup (with controller)You must define three TCP/IP settings for the MasterSwitch VM before it can operate on t
®®®®USER’S GUIDEmasterswitch vmImmediate Reboot. This action immediately turns an outlet off, and then turns it back on after the outlet’s Reboot Dura
®®®®USER’S GUIDEmasterswitch vmDelayed On. This action turns on an outlet according to its Power On Delay.Outlet is off Delayed On command is issuedPo
®®®®USER’S GUIDEmasterswitch vmDelayed Off. This action turns off an outlet according to its Power Off Delay.. Outlet is on Delayed Off command is iss
®®®®USER’S GUIDEmasterswitch vmDelayed Reboot. This action turns an outlet off after the outlet’s Power Off Delay expires. Once the outlet’s Reboot Du
®®®®USER’S GUIDEmasterswitch vmSequenced Reboot: This action is available only through Master Outlet Control. Initiating this action immediately power
®®®®USER’S GUIDEmasterswitch vmDelayed Sequenced Reboot. This action is available only through Master Outlet Control. Initiating this action turns off
®®®®USER’S GUIDEmasterswitch vmMasterSwitch VMAP9227 and AP9228➊➋➌➍➎➏➐➑Always-on outlet: Provides continuous power to outlets.Switched outlet: Provi
®®®®USER’S GUIDEmasterswitch vmCurrent sensingEach MasterSwitch VM unit is equipped with a sensor that measures the total current being used by the un
®®®®USER’S GUIDEmasterswitch vmOverload Outlet RestrictionsOutlet Restrictions prevents users from turning on outlets when the current sensor detects
®®®®USER’S GUIDEmasterswitch vmManagementManagement InterfacesInterface options and their access precedenceAfter you have configured MasterSwitch VM w
®®®®USER’S GUIDEmasterswitch vmWeb interfaceTo access and log on to the MasterSwitch VM unit’s Web interface, perform these steps:1. In the URL Locati
®®®®USER’S GUIDEmasterswitch vmControl Console interfaceYou can manage MasterSwitch VM through the Control Console remotely by using Telnet or locally
®®®®USER’S GUIDEmasterswitch vmSelecting menu items. To select a menu item, type its number, and press ENTER. For menus that configure values, always
®®®®USER’S GUIDEmasterswitch vmPassword-Protected AccountsMasterSwitch VM, when used with the controller (AP9224) provides three types of password-pro
®®®®USER’S GUIDEmasterswitch vmAccount access to outlets and menu itemsAdministrator and Device Manager accounts have access to all outlets. The Admin
®®®®USER’S GUIDEmasterswitch vmMenu ItemsOutletsControl actionsYou can perform Outlet Control Actions on individual outlets (by Individual Outlet Cont
®®®®USER’S GUIDEmasterswitch vmSynchronized set configurationOutlets that are members of a synchronization set will all execute the same control actio
®®®®USER’S GUIDEmasterswitch vmNoteThe power cord of the AP9227 model has a NEMA 5-15 plug, and the power cord of the AP9228 model has a NEMA L5-20 pl
®®®®USER’S GUIDEmasterswitch vmMasterSwitch VMUnit ConfigurationItem DefinitionName Name of the MasterSwitch VM unit (23 characters maximum)Cold Start
®®®®USER’S GUIDEmasterswitch vmOutlet ConfigurationOutlet Configuration: LinksItem DefinitionOutletIdentifies each outlet, the unit to which the outle
®®®®USER’S GUIDEmasterswitch vmEvent LogThe log in the Web and Control Console interfacesThe event log displays the MasterSwitch VM unit’s last 300 ev
®®®®USER’S GUIDEmasterswitch vmRetrieving the event log using the FTP interfaceTo retrieve the event log, type get event.txt. The MasterSwitch VM unit
®®®®USER’S GUIDEmasterswitch vmDeleting an event log in the FTP interfaceTo delete the event log, type del event.txt. No confirmation is required. A n
®®®®USER’S GUIDEmasterswitch vmNetworkTCP/IPTFTP/FTPItem DefinitionSystem IP The IP address of the unit.Subnet Mask The network subnet mask.Default Ga
®®®®USER’S GUIDEmasterswitch vmTelnet/WebSNMPItem DefinitionTe ln etAccess Enables or Disables Telnet Access.PortThe TCP/IP port where the Telnet serv
®®®®USER’S GUIDEmasterswitch vmSNMP: Access ControlItem DefinitionCommunity NameThe password that the NMS (identified by the NMS IP option) must use f
®®®®USER’S GUIDEmasterswitch vmSNMP: Trap ReceiverItem DefinitionCommunity NameThe password that the unit uses when it sends traps to the NMS identifi
®®®®USER’S GUIDEmasterswitch vmSystemUser ManagerYou configure the properties of the Administrator and Device Manager under the User Manager section.T
®®®®USER’S GUIDEmasterswitch vmAP9229Switched outlet: Provides individually managed power control to outlets.Outlet status LED: Indicates the state
®®®®USER’S GUIDEmasterswitch vmOutlet User ManagerYou can create up to 16 independent Outlet User accounts for the MasterSwitch VM unit. Each Outlet U
®®®®USER’S GUIDEmasterswitch vmIdentificationDate/TimeItem DefinitionNameThe system name used to identify the device. This name will be used for the s
®®®®USER’S GUIDEmasterswitch vmFile TransferItem DefinitionDescribe the Current Transfer SettingsRemote TFTP Server IPThe IP address of the remote TFT
®®®®USER’S GUIDEmasterswitch vmToolsLinks Item DefinitionNo Action Causes no actionReboot CardRestarts the management card operation, but does not aff
®®®®USER’S GUIDEmasterswitch vmHelpTypes of HelpMasterSwitch provides help menus on each interface. On the Web interface, the Help menu is located on
®®®®USER’S GUIDEmasterswitch vmSecuritySecurity FeaturesPlanning and implementing security featuresAs a network device that passes information across
®®®®USER’S GUIDEmasterswitch vmUser names, passwords, community namesAll user names, passwords, and community names for SNMP are transferred over the
®®®®USER’S GUIDEmasterswitch vmAuthenticationAuthentication versus encryptionThe MasterSwitch VM controls access by providing basic authentication thr
®®®®USER’S GUIDEmasterswitch vmMD5 authentication (for the Web interface)The Web interface option for MD5 authentication enables a higher level of acc
®®®®USER’S GUIDEmasterswitch vmSummary of access methodsInterface Security Access NotesSerial Control ConsoleAccess is by user name and password.Alway
®®®®USER’S GUIDEmasterswitch vmNoteThe AP9229 model has an IEC C20 inlet, but no attached power cord. An IEC 320 C19 to C20 power cord (960-0025) is p
®®®®USER’S GUIDEmasterswitch vmProduct InformationSpecificationsAP9227 & AP9228 specifications (MasterSwitch VM)ElectricalInputNominal input volta
®®®®USER’S GUIDEmasterswitch vmAP9227 & AP9228 approvals (MasterSwitch VM)EMC verification FCC Class A, VCCISafety Agency AP9227: UL, cUL. AP9228:
®®®®USER’S GUIDEmasterswitch vmAP9229 specifications (MasterSwitch VM)AP9229 approvals (MasterSwitch VM)ElectricalInputNominal input voltageNominal in
®®®®USER’S GUIDEmasterswitch vmAP9224 specifications (MasterSwitch VM controller)AP9224 approvals (MasterSwitch VM controller)ElectricalInputNominal i
®®®®USER’S GUIDEmasterswitch vmWarranty and ServiceLimited warrantyAPC warrants the MasterSwitch VM unit and controller to be free from defects in mat
®®®®USER’S GUIDEmasterswitch vmObtaining serviceTo obtain support for problems with your MasterSwitch VM unit and controller:01. Note the serial numbe
®®®®USER’S GUIDEmasterswitch vmLife-Support PolicyGeneral policyAmerican Power Conversion (APC) does not recommend the use of any of its products in t
®®®®USER’S GUIDEmasterswitch vmAPC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of th
®®®®USER’S GUIDEmasterswitch vmCopyrightEntire contents copyright © 2002 American Power Conversion. All rights reserved. Reproduction in whole or in p
®®®®USER’S GUIDEmasterswitch vmMasterSwitch VM ControllerAP9224➊➋➌➏➐➎➍Front ViewRear ViewStatus LED: Indicates whether the controller is receiving po
®®®®USER’S GUIDEmasterswitch vmLEDsMasterSwitch VM LEDsLED Status DescriptionMasterSwitch VM OutletsOn The outlet is on.Off The outlet is off.MasterSw
®®®®USER’S GUIDEmasterswitch vmController LEDsLED Status DescriptionController Front StatusOn The controller has power.Off The controller has no powe
®®®®USER’S GUIDEmasterswitch vmOperationSetup and Outlet ConfigurationInitial setup (no controller)The Com2Telnet program, provided on the MasterSwitc