APC 208 VAC User Manual

Browse online or download User Manual for Power supply units APC 208 VAC. Nominal output voltage 120/208/240 100/200 Vac Output voltage

  • Download
  • Add to my manuals
  • Print
  • Page
    / 11
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Operation North American Model Worldwide Model Japanese Model
Power Capacity (kVA) 4-16kVA 4-16kVA 4-16kVA
Battery type Hot swappable, sealed, maintenance-free lead acid batteries with 3-5 year typical lifetime.
Recharge time with supplied packs <3 hours
Extended Battery Option Yes
Topology Double conversion on-line
Input Specifications
Nominal input voltage 208 or 240 Vac 220/230/240 Vac (1:1 phase or 3:1 phase) 200 Vac
Nominal Input frequency 60Hz 50/60Hz 50/60Hz
Input voltage range 155Vac to 276Vac 155Vac to 276Vac 155Vac to 276Vac
Input frequency range 57-63 Hz or synch 47-63 Hz or synch 47-63 Hz or synch
Standard connections Hardwire
Power factor correction supported >0.98
Output Specifications
Nominal output voltage 120/208/240 220/230/240 Vac 100/200 Vac
Output voltage regulation +/- 3% +/- 3% +/- 3%
Total voltage harmonic distortion <5% at full load
Power factor tolerance Loads with .5 to 1.0 power factor
Efficiency at full load >87% >90% >87%
Load crest factor supported up to 5:1
Overload capacity 50% for 30 seconds, 25% for 10 minutes
Features
N+1 Redundancy capability Yes Yes Yes
Power (kVA) Expandability Yes Yes Yes
Runtime (battery) Expandability Yes Yes Yes
Self Diagnostics Yes Yes Yes
User Serviceable Yes Yes Yes
Automatic bypass Yes Yes Yes
Manual bypass Yes Yes Yes
Indicators, Interfaces, and Controls
LCD Display Programmable 4 X 24 character backlit LCD, multiple languages (English, French, Spanish, Italian, German)
Intelligent serial interface Yes Yes Yes
SNMP Capability Yes Yes Yes
Multiple server/operating system shutdown via Share-UPS via Share-UPS via Share-UPS
Modem (out of band) control via Call-UPS via Call-UPS via Call-UPS
Emergency Power Off (EPO) capability input for external EPO closure input for external EPO closure input for external EPO closure
Environmental Monitoring/dry contact closures via Measure-UPS via Measure-UPS via Measure-UPS
Physical
Ambient Operation 0 to 40 C; 0 to 95% non condensing; up to 10,000 feet
MiniFrame dimensions (hxwxd) 31”x24”x27” (78,7x60,9x68,6cm) 31”x24”x27” (78,7x60,9x68,6 cm) 31”x24”x27” (78,7x60,9x68,6 cm)
MasterFrame dimensions (hxwxd) 52”x24”x27” (132.1x60,9x68,6cm) 45”x24”x27” (114,3x60,9x68,6cm) 52”x24”x27” (132.1x60,9x68,6cm)
Warranty and Service Options
Standard warranty 2 years, including battery 2 years, including battery 2 years, including battery
On-site service Optional Optional Optional
Extended warranty Optional Optional Optional
Symmetra Orderable SKU’s
System Description FRAME 208/240V (Domestic) w/PDU 220-240V 1:1 (Inter’l) 220-240V 3:1 (Inter’l) 200V (Japan)
Symmetra 4kVA Exp. to 8kVA MiniFrame SY4KEX-PD SY4KEXI SY4KEX3I SY4KEXJ
Symmetra 8kVA MiniFrame SY8K-PD SY8KI SY8K3I SY8KJ
Symmetra 8kVA Exp. to16kVA MasterFrame SY8KEX-PD SY8KEXI SY8KEX3I SY8KEXJ
Symmetra 12kVA Exp. to16kVA MasterFrame SY12KEX-PD SY12KEXI SY12KEX3I SY12KEXJ
Symmetra 16kVA MasterFrame SY16K-PD SY16KI SY16K3I SY16KJ
SYPM Symmetra Power Module - for redundancy or expandability
SYBATT Symmetra Battery Module
SYXR4 4 Battery Extended Run Battery Frames
SYXR12 12 Battery Extended Run Battery Frames
996-0884B
Page view 0
1 2 3 4 5 6 ... 10 11

Summary of Contents

Page 1 - 996-0884B

Operation North American Model Worldwide Model Japanese ModelPower Capacity (kVA)

Page 2 - Total Solution

ConfigurationPower Array provides the flexibity to meetthe needs of any mid-size datacenter.Power Modules(PM’s): 4kVA UPS“building blocks”Contain the

Page 3

Configuration GuideConfigure your Symmetra system as follows:STEP 1: Choose the Symmetra system you needbased on your current VA load and future need

Page 4 - Scalability

Advances in enterprise computing and storage tech-nologies are demanding a change in enterprise power pro-tection technology. Today's computer ro

Page 5 - Redundancy

Introducing Symmetra™, the World’sFirst Power Array™, and the Foundationfor Building Near-ContinuousAvailability Power Systems.

Page 6 - Serviceability

IS Managers want to be able to “pay as they grow” to meetthe computing demands of the future. Changes in datacenterpower requirements can make cost-ef

Page 7 - ROI Worksheet

N+1 Redundancy ensures maximum uptimeand continuous availability.RedundancySymmetra achieves N+1 redundancy through a new power sharing technology.Pow

Page 8 - Manageability

Service Made EasyBecause legacy UPSs are not modular, they require a specialUPS technician for service. With only a handful of these propri-etary tech

Page 9 - Management Accessories

EventBattery fails or needs replacementElectronics failLoad capacity reachedOverloadHumidity too highTemperature too highServer locked upLegacy UPSSys

Page 10 - Configuration

ManageabilityBuild a customized UPS managementstrategy with Symmetra accessories.SNMPManagementAPC’s PowerNet SNMPproducts give youenterprise powerman

Page 11 - Configuration Guide

SmartSlot™Accessories providecustom ManagementSymmetra comes equipped with four SmartSlots,the unique accessory bays that allow you to slidevarious ac