InstallationSmart-UPS® VTin Parallel10-40 kVA380/400/415 V208/220 V200/208 V
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel61. Route the cables (UPSs apart)Note: If the UPS system is go
7Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelRoute the PBus cables to UPS 2 and to the slots on the left
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel82. Route the cables (UPSs together via interconnection plates
9Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelFrom UPS 1: Route the two PBus cables to the slots on the le
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel103. Route the cables with conduits (UPSs apart - top cabling)
11Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelAnchor the UPS Parallel System to the FloorHole positions fo
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel12Install the floor anchoring brackets Position the floor anc
13Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelPower Connections (Overview) 380/400/415 V inputMaintenance
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel14Breaker sizes 380/400/415 VQ3 in capacity systems. Q4 in cap
15Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelQ2 in capacity and redundant systems. Note: Note: If fuses a
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel16Breaker sizes 200/208/220 VQ3 in capacity systems. Q4 in cap
17Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelContact InformationFor local, country-specific centers: go t
12/2008990-3045D-001*990-3045D-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any o
ContentsSmart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V iSafety ...
1Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelSafetyIMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel2Schematic overview of the PBus cables layoutNote: The cables
3Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelInterconnection PlatesNote: The enclosures in a parallel syst
Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in Parallel4Install the interconnection platesLift off the side panels.
5Smart-UPS® VT 10-40 kVA 380/400/415 V - 208/220 V - 200/208 V Installation in ParallelBolt the two enclosures together, usingxthe six M6 screws, w