Summary of Contents

Page 1 - Operation

OperationSymmetra®MW IIWith External BypassStatic Switch~~

Page 2

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0016Note: Operation/configuration must be done at the UPS. Note: The ev

Page 3 - Contents

7Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001OperationOperation ModesNormal operationDuring online operation, th

Page 4

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0018Static bypass operationDuring static bypass operation, the critical

Page 5 - Overview

9Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001Operation ProceduresHow to access screens protected by the user-pas

Page 6 - Screen symbols

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001103. Follow the procedure on the screen which is specific to your sy

Page 7 - Breakers

11Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0014. The UPS Startup screen appears with the Charge DC Capacitors st

Page 8

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-00112How to transfer from static bypass to normal operation1. Press the

Page 9 - Display

13Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001ConfigurationHow to Configure the SystemThe UPS is configured from

Page 10

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-00114How to change the password1. Press the Password Settings button on

Page 11 - Battery operation

15Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001How to configure the Touch-Screen settings screen1. Press the Touc

Page 13 - Operation Procedures

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001162. Change the modbus settings:– BMS modbus RTU address: The modbus

Page 14

17Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001How to configure the Network Configuration screensAll network sett

Page 15

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-00118Note: The display will have to be rebooted in order for the change

Page 16

19Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0015. Configure the Remote Monitoring Service Settings screen. The AP

Page 17 - Configuration

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001206. Configure the APC ISX Settings screen:– Enable ISX discovery: P

Page 18 - How to change the password

21Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0012. Change the display settings:– Enable APC Q breaker prefix: Use

Page 20

23Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001MaintenancePredictive Maintenance ScreensThe Predictive Maintenanc

Page 21

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-00124Inverter AC Capacitors screenThe Inverter AC Capacitor screen disp

Page 22

25Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001• Stress Status: Shows the actual status of the Main Static Switc

Page 23

ContentsSymmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001 iOverview ...

Page 24

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-00126Note: Note the orientation of the air filter.4. Remove the air fil

Page 25

27Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001TroubleshootingAlarm TypesThe color of the top of the screen chang

Page 26

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-00128How to view active alarmsNote: The Active Alarms screen includes a

Page 27 - Inverter DC Capacitors screen

29Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001• Refresh: Press the Refresh button to update the Event Log.• St

Page 30

3/2009990-1377E-001*990-1377E-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of

Page 31 - Troubleshooting

ii Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001Configuration ...

Page 32 - How to view the event log

1Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001OverviewNavigation TreeThe UPS display is the user interface to the

Page 33

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0012Display Symbols and ButtonsNavigation symbolsScreen symbolsHome: Go

Page 34

3Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001Buttons1. ON button: Press this button to switch ON the UPS or the

Page 35

Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-0014How to Access Summary Screens from the UPSThe UPS Summary screen pr

Page 36 - *990-1377E-001*

5Symmetra MW II with External Bypass Static Switch Operation Manual - 990-1377E-001How to Access Summary Screens from the External Bypass Static Switc