MGE
TM
Galaxy
TM
7000
250 - 500 kVA
Installation manual
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - 250 - 500 kVA

MGETM GalaxyTM 7000250 - 500 kVAInstallation manual

Page 2 - Introduction

34020846EN/AD - Page 101. Installation1.1 Possible installationsSingle or modular UPS alone Parallel UPS systems (8 units maximum)Modular UPSs in para

Page 3 - Safety rules

Possible installations >34020846EN/AD - Page 111. InstallationParallel UPSs with SSC (static-switch cabinet) Parallel UPS with SSC and SSC maintena

Page 4 - Foreword

Possible installations >34020846EN/AD - Page 121. InstallationUPS set up as a frequency converter (with or without battery, maximum eight units)Sin

Page 5 - Environment

Layout >34020846EN/AD - Page 131. Installation1.2 LayoutDimensionsWeightsWeight values are purely indicative. See the packing labels for the precis

Page 6 - Contents

Layout >34020846EN/AD - Page 141. InstallationFloor mounting Normal or false floor.UPS cabinets SSC800 and 1200 kVA2000 kVADimensions are indicated

Page 7

Layout > Floor mounting34020846EN/AD - Page 151. Installation2000 kVA lightExternal bypass or SSC maintenance cabinets 800 and 1200 kVA2000 kVA

Page 8

Layout > Floor mounting34020846EN/AD - Page 161. InstallationAuxiliary cabinets (empty) Backfeed cabinet Max. load on floor per square cm for th

Page 9

Layout >34020846EN/AD - Page 171. InstallationPosition in roomUPS cabinetsSSCsLayout example for an SSC with two parallel UPS units External bypass

Page 10 - 1. Installation

Layout >34020846EN/AD - Page 181. InstallationVentilation UPS cabinetsSSC cabinetsPn = rated power, for other values please consult the after-sales

Page 11

Prerequisites >34020846EN/AD - Page 191. Installation1.3 PrerequisitesUPS currentsRecommended upstream protection Normal AC source Bypass AC sour

Page 12

34020846EN/AD - Page 2Introduction Thank you for selecting an APC by Schneider Electric product to protect your electrical equipment.The MGETM Ga

Page 13

Prerequisites >34020846EN/AD - Page 201. InstallationRecommended maximum downstream protection Battery protection Pn = rated power at a power fact

Page 14

Prerequisites >34020846EN/AD - Page 211. InstallationCharacteristics of the connection terminals UPS cabinetsSSCs, SSC maintenance, External bypass

Page 15

Prerequisites >34020846EN/AD - Page 221. InstallationPower cables for parallel UPSs Normal AC line and batteryBypass AC line and loadModular UPSs i

Page 16

Prerequisites > Power cables for parallel UPSs34020846EN/AD - Page 231. InstallationModular UPSs in parallel with external bypass cabinet 1 Do not

Page 17

System earthing arrangements >34020846EN/AD - Page 241. Installation1.4 System earthing arrangementsThis section lists the main SEAs (system earthi

Page 18

System earthing arrangements >34020846EN/AD - Page 251. InstallationTNC upstream, TNC, TNS or TT downstream installationFor separate normal and byp

Page 19

Adapting the cabinet according to the neutral point connection >34020846EN/AD - Page 261. Installation1.5 Adapting the cabinet according to the neu

Page 20

Connecting the power cables >34020846EN/AD - Page 271. Installation1.6 Connecting the power cablesSingle or modular UPS cabinet250 to 400 kVARemove

Page 21

Connecting the power cables > Single or modular UPS cabinet34020846EN/AD - Page 281. Installation500 kVARemove the protective coversThis operation

Page 22

Connecting the power cables >34020846EN/AD - Page 291. InstallationFrequency-converter cabinet250 to 400 kVARemove the protective coversIn parallel

Page 23

34020846EN/AD - Page 3SafetySafety rulesSafety of persons Product safety◗ Protection (circuit breaker/switch disconnector) must be installed upstream

Page 24

Connecting the power cables > Frequency-converter cabinet34020846EN/AD - Page 301. Installation500 kVARemove the protective coversIn parallel syst

Page 25

Connecting the power cables >34020846EN/AD - Page 311. InstallationParallel UPS cabinet250 to 400 kVARemove the protective coversIn parallel system

Page 26

Connecting the power cables > Parallel UPS cabinet34020846EN/AD - Page 321. Installation500 kVARemove the protective coversIn parallel systems wit

Page 27

Connecting the power cables >34020846EN/AD - Page 331. InstallationSSC cabinet800 kVARemove the protective coversThis operation must be carried out

Page 28

Connecting the power cables > SSC cabinet34020846EN/AD - Page 341. Installation1200 kVARemove the protective coversThis operation must be carried

Page 29

Connecting the power cables > SSC cabinet34020846EN/AD - Page 351. Installation2000 kVARemove the protective coversYou must have first assembled b

Page 30

Connecting the power cables > SSC cabinet > 2000 kVA34020846EN/AD - Page 361. InstallationConnecting the power cablesThis operation must be car

Page 31

Connecting the power cables > SSC cabinet34020846EN/AD - Page 371. Installation2000 kVA lightRemove the protective coversThis operation may only b

Page 32

Connecting the power cables > SSC cabinet > 2000 kVA light34020846EN/AD - Page 381. InstallationConnect the cablesThis operation may only be ca

Page 33

Connecting the power cables >34020846EN/AD - Page 391. InstallationExternal bypass cabinet800 kVARemove the protective coversThis operation must be

Page 34

34020846EN/AD - Page 4ForewordPictograms Document Danger, these instruction are imperative. Audio signal.Information, advice, help. LED offVisua

Page 35

Connecting the power cables > External bypass cabinet34020846EN/AD - Page 401. Installation1200 kVARemove the protective coversThis operation must

Page 36

Connecting the power cables > External bypass cabinet34020846EN/AD - Page 411. Installation2000 kVARemove the protective coversThis operation must

Page 37

Connecting the power cables >34020846EN/AD - Page 421. InstallationSSC maintenance cabinet800 and 1200 kVARemove the protective coversThis operatio

Page 38

Connecting the power cables > SSC maintenance cabinet34020846EN/AD - Page 431. Installation2000 kVAThis operation may only be carried out by autho

Page 39

Connecting cabinet ECPs (exposed conductive parts) >34020846EN/AD - Page 441. Installation1.7 Connecting cabinet ECPs (exposed conductive parts)Val

Page 40

Connect the backfeed option >34020846EN/AD - Page 451. Installation1.9 Connect the backfeed optionThe backfeed option is compulsory if IEC 62040-1-

Page 41

Connecting the control-wire cables >34020846EN/AD - Page 461. Installation1.10 Connecting the control-wire cablesConnecting a modular UPS or freque

Page 42

Connecting the control-wire cables >34020846EN/AD - Page 471. InstallationConnecting the UPS units in parallelConnecting the modular UPS units in p

Page 43

Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AD - Page 481. InstallationConnecting the modular UPSs with th

Page 44

Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AD - Page 491. InstallationConnecting parallel UPSs with SSC (

Page 45

34020846EN/AD - Page 5EnvironmentAPC by Schneider Electric has implemented an environmental-protection policy.Products are developed according to an e

Page 46

Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AD - Page 501. InstallationConnect the components specific to

Page 47

Connecting the control-wire cables >34020846EN/AD - Page 511. InstallationConnecting the EPO function This operation must be carried out by qualifi

Page 48

Connecting the control-wire cables >34020846EN/AD - Page 521. InstallationConnecting the dry-contact communication card This operation must be carr

Page 49

Assembling and connecting the external battery cabinet >34020846EN/AD - Page 531. Installation1.11 Assembling and connecting the external battery c

Page 50

Assembling and connecting the external battery cabinet > Connecting the power cables34020846EN/AD - Page 541. InstallationConnecting the power cab

Page 51

Assembling and connecting the external battery cabinet >34020846EN/AD - Page 551. InstallationConnecting the control-wire cablesConnecting the batt

Page 52

Assembling and connecting the external battery cabinet > Connecting the control-wire cables34020846EN/AD - Page 561. InstallationConnecting the ba

Page 53

Assembling and connecting the external battery cabinet > Connecting the control-wire cables34020846EN/AD - Page 571. InstallationConnecting a sens

Page 54

34020846EN/AD - Page 582. Appendices2.1 Assembling 2000 kVA SSCs2.2 IP 32 optionRefer to the "IP 32" manual no. 3460028300 for more details

Page 55

Electrical characteristics >34020846EN/AD - Page 592. Appendices2.3 Electrical characteristicsSelection of protection devices UPS short-circuit cur

Page 56

34020846EN/AD - Page 6Contents1. Installation 1.1 Possible installations ...

Page 57

Electrical characteristics >34020846EN/AD - Page 602. AppendicesLine-current values Permissible UPS overloads as a function of time Rated power

Page 58 - 2. Appendices

General characteristics of MGE TM Galaxy TM 7000 UPSs >34020846EN/AD - Page 612. Appendices2.4 General characteristics of MGE TM Galaxy TM 7000 UPS

Page 59

General characteristics of MGE TM Galaxy TM 7000 UPSs >34020846EN/AD - Page 622. AppendicesBattery characteristics Sealed lead-acid battery Vented

Page 60

Glossary >34020846EN/AD - Page 632. Appendices2.5 Glossary Backup time Time that the connected loads can operate on battery power.Bypass AC source

Page 61

34020846EN/AD

Page 62

34020846EN/AD - Page 7ContentsSSC cabinet or external bypass cabinet ...

Page 63

34020846EN/AD - Page 8Contents 2.1 Assembling 2000 kVA SSCs .......

Page 64 - 34020846EN/AD

34020846EN/AD - Page 9Contents