APC Back-UPS 750VA Specifications

Browse online or download Specifications for Uninterruptible power supplies (UPSs) APC Back-UPS 750VA. APC Back-UPS 750VA User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation and Operation
Back-UPS
®
BE750G Series
Safety
Specifications
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there
is excessive dust or humidity.
Connect the Back-UPS power cord directly to a wall outlet. Do not use a surge
protector or an extension cord.
Input
Voltage 120 Vac Nominal
Frequency 50 Hz/60 Hz auto sensing
Brownout Transfers 92 Vrms Typical
Over-voltage Transfer 139 Vrms Typical
Output
UPS Capacity
(5 battery backup outlets)
750 VA, 450 W
Total Amperage (all outlets) 12 A (including UPS output)
Voltage - On Battery 115 Vrms ± 8% step approximated sine wave
Frequency - On Battery 50 Hz/60 Hz ± 1 Hz
Transfer Time 6 ms Typical, 10 ms maximum
Protection and
Filtering
AC Surge Protection Full time, 354 Joules
Phone/DSL/FAX surge protection Single line (2 wire)
Cable/CAT V/DSS surge protection One coax input/output
Network surge protection 10/100 Base -T ethernet
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid
Replacement battery cartridge RBC17
Average Life 3 - 5 years depending on the number of discharge cycles and
environmental temperature
Physical
Net Weight 11 lb (5 kg)
Dimensions
Length x Width x Height
14 in x 7 in x 4 in
36 cm x 18 cm x 9 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - BE750G Series

Installation and Operation Back-UPS® BE750G SeriesSafetySpecificationsThis unit is intended for indoor use only. Do not operate this unit in direct su

Page 2 - Connect Equipment

Back-UPS BE750G Series2Connect the BatteryThe Back-UPS is shipped with one battery cable disconnected. Remove the “Stop! Connect the Battery” label th

Page 3 - Personal Edition Software

Back-UPS BE750G Series 3Connect Modem/Telephone/DSL/FAX/10/100 Base-T Network CableThe Back-UPS protects a single line, 2 wire telephone line, includi

Page 4 - Turn On the Back-UPS

Back-UPS BE750G Series4Turn On the Back-UPSPress the Power ON button located on the top of the Back-UPS. The Power On/Replace Battery LED will illumin

Page 5 - Terminates

Back-UPS BE750G Series 5Status IndicatorsStatus LED Indicator Audible Indicator OnAudible Indicator TerminatesPower On The Back-UPS is supplying utili

Page 6 - Input Voltage Range

Back-UPS BE750G Series6Voltage Sensitivity AdjustmentThe Back-UPS detects and reacts to line voltage distortions by transferring to battery backup pow

Page 7 - Troubleshooting

Back-UPS BE750G Series 7TroubleshootingProblem and Possible Cause SolutionThe Back-UPS will not turn onThe Back-UPS has not been turned on. Press the

Page 8 - Warranty

990-3952B7/2011© 2011 APC by Schneider Electric. APC, the APC logo, Back-UPS, and PowerChute are owned by Schneider Electric Industries S.A.S., Ameri