MGE™ Galaxy™ 7000160 - 500 kVAInstallation manualSingle UPSModular UPSParallel UPS with SSCFrequency convertersStatic-switch cabinet
Possible installations > Parallel UPS systems34020846EN/AE - Page 101. InstallationParallel UPSs with SSC (static-switch cabinet) Parallel UPSs wi
Possible installations >34020846EN/AE - Page 111. InstallationUPS set up as a frequency converter (with or without battery, maximum eight units)Sin
Layout >34020846EN/AE - Page 121. Installation1.2 LayoutDimensionsWeightsWeight values are purely indicative. See the packing labels for the precis
Layout >34020846EN/AE - Page 131. InstallationFloor mounting Normal or false floor.UPS cabinets SSC800 and 1200 kVA2000 kVADimensions are indicated
Layout > Floor mounting34020846EN/AE - Page 141. Installation2000 kVA light External bypass or SSC maintenance cabinets 800 and 1200 kVA2000 kVA
Layout > Floor mounting34020846EN/AE - Page 151. InstallationAuxiliary cabinets (empty) Backfeed cabinet Max. load on floor per square cm for
Layout >34020846EN/AE - Page 161. InstallationPosition in room UPS cabinetsSSCsLayout example for an SSC with two parallel UPS units External bypas
Layout >34020846EN/AE - Page 171. InstallationVentilation UPS cabinetsSSCsPn = rated power; for other values, please consult the after-sales suppor
Prerequisites >34020846EN/AE - Page 181. Installation1.3 PrerequisitesUPS currentsRecommended upstream protection Normal AC source Bypass AC sour
Prerequisites >34020846EN/AE - Page 191. InstallationRecommended maximum downstream protection Battery protection Pn = rated power at a power fact
34020846EN/AE - Page 2Introduction Thank you for selecting an APC by Schneider Electric product to protect your electrical equipment.The MGE™ Gal
Prerequisites >34020846EN/AE - Page 201. InstallationCharacteristics of the connection terminals UPS cabinets* Maximum tightening torque: 25 N.mSSC
Prerequisites >34020846EN/AE - Page 211. InstallationPower cables for parallel UPSs Normal AC line and batteryBypass AC line and loadModular UPSs i
Prerequisites > Power cables for parallel UPSs34020846EN/AE - Page 221. InstallationFrequency converters 1 Do not include redundant UPS units.Modu
Prerequisites > Power cables for parallel UPSs34020846EN/AE - Page 231. InstallationParallel UPSs with SSC (static-switch cabinet) 1 Do not includ
System earthing arrangements >34020846EN/AE - Page 241. Installation1.4 System earthing arrangementsThis section lists the main SEAs (system earthi
System earthing arrangements > Parallel UPS systems34020846EN/AE - Page 251. InstallationTNC upstream, TNC, TNS or TT downstream installation For
Adapting the cabinet according to the neutral point connection >34020846EN/AE - Page 261. Installation1.5 Adapting the cabinet according to the neu
Connecting the power cables >34020846EN/AE - Page 271. Installation1.6 Connecting the power cablesSingle or modular UPS cabinet 160 to 400 kVARemov
Connecting the power cables > Single or modular UPS cabinet34020846EN/AE - Page 281. Installation500 kVARemove the protective coversThis operation
Connecting the power cables >34020846EN/AE - Page 291. InstallationFrequency-converter cabinet160 to 400 kVARemove the protective coversIn parallel
34020846EN/AE - Page 3ForewordPictograms Document Danger, these instructions are imperative Audio signalInformation, advice, help. LED offVisual
Connecting the power cables > Frequency-converter cabinet34020846EN/AE - Page 301. Installation500 kVARemove the protective coversIn parallel syst
Connecting the power cables >34020846EN/AE - Page 311. InstallationParallel UPS cabinet250 to 400 kVARemove the protective coversIn parallel system
Connecting the power cables > Parallel UPS cabinet34020846EN/AE - Page 321. Installation500 kVARemove the protective coversIn parallel systems wit
Connecting the power cables >34020846EN/AE - Page 331. InstallationStatic-switch cabinet800 kVARemove the protective coversThis operation must be c
Connecting the power cables > Static-switch cabinet34020846EN/AE - Page 341. Installation1200 kVARemove the protective coversThis operation must b
Connecting the power cables > Static-switch cabinet34020846EN/AE - Page 351. Installation2000 kVARemove the protective coversYou must have first a
Connecting the power cables > Static-switch cabinet > 2000 kVA34020846EN/AE - Page 361. InstallationConnecting the power cablesThis operation m
Connecting the power cables > Static-switch cabinet34020846EN/AE - Page 371. Installation2000 kVA lightRemove the protective coversThis operation
Connecting the power cables > Static-switch cabinet > 2000 kVA light34020846EN/AE - Page 381. InstallationConnecting the power cablesThis opera
Connecting the power cables >34020846EN/AE - Page 391. InstallationExternal bypass cabinet800 kVARemove the protective coversThis operation must be
34020846EN/AE - Page 4SafetySafety rulesSafety of persons Product safety◗ Protection (circuit breaker/switch disconnector) must be installed upstream
Connecting the power cables > External bypass cabinet34020846EN/AE - Page 401. Installation1200 kVARemove the protective coversThis operation must
Connecting the power cables > External bypass cabinet34020846EN/AE - Page 411. Installation2000 kVARemove the protective coversThis operation must
Connecting the power cables >34020846EN/AE - Page 421. InstallationSSC maintenance cabinet800 and 1200 kVARemove the protective coversThis operatio
Connecting the power cables > SSC maintenance cabinet34020846EN/AE - Page 431. Installation2000 kVARemove the protective coversThis operation must
Connecting cabinet ECPs (exposed conductive parts) >34020846EN/AE - Page 441. Installation1.7 Connecting cabinet ECPs (exposed conductive parts)Val
Connect the backfeed option >34020846EN/AE - Page 451. Installation1.9 Connect the backfeed optionThe backfeed option on normal and bypass AC input
Connecting the control-wire cables >34020846EN/AE - Page 461. Installation1.10 Connecting the control-wire cablesConnecting a modular UPS or freque
Connecting the control-wire cables >34020846EN/AE - Page 471. InstallationConnecting the UPS units in parallelConnecting the modular UPS units in p
Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AE - Page 481. InstallationConnecting the modular UPSs with th
Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AE - Page 491. InstallationConnecting parallel UPSs with SSC (
34020846EN/AE - Page 5EnvironmentAPC by Schneider Electric has implemented an environmental protection policy.Products are developed according to an e
Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AE - Page 501. InstallationConnect the components specific to
Connecting the control-wire cables > Connecting the UPS units in parallel > Connect the components specific to the 2000 kVA light SSC34020846EN
Connecting the control-wire cables > Connecting the UPS units in parallel34020846EN/AE - Page 521. InstallationConnect the SSC maintenance cabinet
Connecting the control-wire cables >34020846EN/AE - Page 531. InstallationConnecting the EPO function This operation must be carried out by qualifi
Connecting the control-wire cables >34020846EN/AE - Page 541. InstallationConnecting the dry-contact communication card This operation must be carr
Coupling the 400 mm auxiliary cabinet >34020846EN/AE - Page 551. Installation1.11 Coupling the 400 mm auxiliary cabinet1 - Remove the two inter-cab
Assembling and connecting the external battery cabinet >34020846EN/AE - Page 561. Installation1.12 Assembling and connecting the external battery c
Assembling and connecting the external battery cabinet >34020846EN/AE - Page 571. InstallationConnecting the power cables4 - Connect the control-wi
Assembling and connecting the external battery cabinet >34020846EN/AE - Page 581. InstallationConnecting the control-wire cablesConnecting the batt
Assembling and connecting the external battery cabinet >34020846EN/AE - Page 591. InstallationConnecting the battery temperature sensor UPS cabinet
34020846EN/AE - Page 6Contents1. Installation 1.1 Possible installations...
34020846EN/AE - Page 60Connecting a sensor to a number of UPS cabinets1 - Connect the UPSs to the temperature sensor in the auxiliary cabinet as per t
Assembling 2000 kVA SSCs >34020846EN/AE - Page 612. Appendices2. Appendices2.1 Assembling 2000 kVA SSCs2.2 IP 32 optionRefer to the "IP 32&quo
Electrical characteristics >34020846EN/AE - Page 622. Appendices2.3 Electrical characteristicsSelection of protection devices UPS short-circuit cur
Electrical characteristics >34020846EN/AE - Page 632. AppendicesPermissible UPS overloads as a function of time NORMAL mode operation Bypass AC m
General characteristics of MGE™ Galaxy™ 7000 UPSs >34020846EN/AE - Page 642. Appendices2.4 General characteristics of MGE™ Galaxy™ 7000 UPSsUPS pow
General characteristics of MGE™ Galaxy™ 7000 UPSs >34020846EN/AE - Page 652. AppendicesBattery characteristics Sealed lead-acid battery Vented lea
Glossary >34020846EN/AE - Page 662. Appendices2.5 Glossary Backup time Time that the connected loads can operate on battery power.Bypass AC source
Glossary >34020846EN/AE - Page 672. Appendices
34020846EN/AE
34020846EN/AE - Page 7Contents1.5 Adapting the cabinet according to the neutral point connection ... 2
34020846EN/AE - Page 8Contents1.12 Assembling and connecting the external battery cabinet.....
34020846EN/AE - Page 91. Installation1.1 Possible installationsSingle or modular UPS alone Parallel UPS systems (8 units maximum)Modular UPSs in paral