Thank you for purchasing APC’s Line-R Automatic Voltage Regulator! Please fill out and
mail the product warranty registration form, or fill out an online form at www.apc.com.
The Line-R automatically corrects brownouts (by boosting low voltage) and overvoltages (by
stepping down high voltage) from the power utility service to levels that are safe for computers,
as well as other sensitive equipment. APC’s Line-R provides the highest degree of protection
from line voltage sags and swells, and has been designed for many years of reliable,
maintenance-free service.
Applications
CAUTION: The total power consumption of all equipment plugged into the Line-R must not
exceed the “Maximum Output Power Capacity” rating listed in the Specifications table. A total
load in excess of this rating will cause the circuit breaker to “trip”.
The Line-R is designed for use with voltage sensitive equipment such as a: computer, monitor,
inkjet printer, scanner or fax. It is also designed for use with home electronics (TVs, stereos,
CD players, etc.).
Appliances not suitable for use with the Line-R are items such as refrigerators, freezers, power
tools, air conditioners, dehumidifiers, blenders, or any device that employs an AC motor for
operation. Not for use with life sustaining equipment and any device with a power requirement
exceeding the “Maximum Output Power Capacity” rating listed in the Specifications table.
Features
Power Switch
The Line-R provides a front panel power switch (l = on) / (O = off) which functions as the
master power switch for the Line-R and all devices connected to the device.
Push Button Circuit Breaker
The Line-R provides a push button circuit breaker on the rear panel of the unit to protect it from
being overloaded. If the circuit breaker “trips”, unplug the last device connected to the unit and
push the circuit breaker fully inward.
w
w
w
.apc.com
®
Line-R
®
Automatic Voltage Regulator
Models LE600I and LE1200I
Lights when input voltage is high.
Flashes when input voltage is above rated Input
Voltage Range.
Input voltage is normal.
Lights when input voltage is low.
Flashes when input voltage is below rated Input
Voltage Range.
Thepower switch applies and removes power to/
from the Line-R
(l = on) / (O = off) .
Power Switch
AC Outlets (4)
(connect equipment here)
User Selectable
Voltage Switch
(see Select Input Voltage)
Push Button
Circuit Breaker
Connect Your
Detachable Device
Power Cord Here and
to an AC Wall Outlet
Connect the Supplied
Power Cord from any
Outlet to Your Device
Installation
Placement - Please install the Line-R in a protected environment free of excessive dust,
mechanical vibration, inflammable gases and explosive or corrosive atmospheres.
Do not block the top or side air vents on the unit. Allow 1 inch (2.5 cm) minimum vent
clearance.
Select Input Voltage - The Line-R provides a three-position User Selectable Voltage
Switch for adjusting the input voltage for the region where it is being used (example: Russia
- 220V, Denmark - 230V, United Kingdom - 240V). Slide the switch to select the proper
voltage for your location.
Plug the Line-R into Wall Outlet - Detach your computer's power cord from the back of
your computer and use it to plug the Line-R into the wall socket. Use one of the two power
cords supplied with the Line-R to reconnect your computer to any of the four outlets on the
back of the Line-R. The Line-R should only be used in buildings having proper grounding
on a branch circuit protected by a fuse or circuit breaker.
Connect Your Equipment - Plug equipment into the Line-R rear-panel outlets and switch the equip-
ment ON. The equipment will not be powered until the Line-R is switched ON.
CAUTION: The total power consumption of all equipment plugged into the Line-R must not exceed
the ratings listed in the Specifications table below. A total load in excess of the listed ratings will cause
the push button circuit breaker to “trip”.
Switch ON the Line-R - Press the front panel power switch to the on (l) position. This switch may be
used as the master switch for the device and all equipment connected to it.
Specifications
Characteristics Model LE600I Model LE1200I
Maximum Output Power Capacity 600 W or 600 VA 1200 W or 1200 VA
Nominal Output Voltage 220, 230, or 240V (User Selectable)
Nominal Input Current 2.6 A 5.2 A
Acceptable Voltage Range Tolerance 160 - 270V (Selector Switch set to 220V)
166 - 280V (Selector Switch set to 230V)
170 - 290V (Selector Switch set to 240V)
Rated Input Voltage 250Vac
Maximum Acceptable Input Voltage 300V
Surge Energy 300 Joules
Output Regulation ±10%
Response Time < 2 AC Cycles
Efficiency >92%
Nominal Frequency 47 - 63 Hz
Number of Outlets 4
Operating Temperature 32 - 104°F (0 - 40°C)
Relative Humidity 0 - 95% Non-condensing
Dimensions 4.6 x 8.4 x 5.5 inches (118 x 214 x 141 mm)
Weight 3.1 kg (6.8 lb) 4.2 kg (9.2 lb)
2.5 cm
(1 inch)
Limited Warranty
American Power Conversion (APC) warrants its products to be free from defects in materials
and workmanship for a period of two years from the date of purchase. Its obligation under this
warranty is limited to repairing or replacing, at its sole option, any such defective products. To
obtain service under warranty you must obtain a Return Material Authorization (RMA)
number from APC or an APC service center. Products must be returned to APC or an APC
service center with transportation charges prepaid and must be accompanied by a brief
description of the problem encountered and proof of date and place of purchase. This warranty
does not apply to equipment which has been damaged by accident, negligence, or
misapplication or has been altered or modified in any way. This warranty applies to the
original purchaser who must have proper registered the product within 10 days of purchase.
EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF
MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some countries
do not permit limitation or exclusion of implied warranties; therefore, the aforesaid
limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT SHALL APC BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as
lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of
data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you
specific legal rights and you may also have other rights which may vary from location to
location.
Contact Information
990-1287 Copyright © 2002 American Power Conversion All rights reserved.
Technical Support http://www.apc.com/support
Internet http://www.apc.com
Europe, Middle East, and Africa +353 91 702020
Worldwide +1.401.789.5735
APC and Line-R are registered trademarks of American Power Conversion.
All other trademarks are the property of their respective owners.
Page view 0
1

Summary of Contents

Page 1 - .apc.com

Thank you for purchasing APC’s Line-R Automatic Voltage Regulator! Please fill out andmail the product warranty registration form, or fill out an onli

Comments to this Manuals

No comments