APC MGE Galaxy 3500 Technical Information

Browse online or download Technical Information for Uninterruptible power supplies (UPSs) APC MGE Galaxy 3500. APC MGE Galaxy 3500 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - 10-30kVA208/220V

MGE™Galaxy™3500Series10-40kVA380/400/415V10-30kVA208/220VOperation

Page 2

Themenutreeprovidesaquickoverviewofthefunctionsandviewsyoumayaccess.ControlTurnLoadOff/OnUPSinto/outofBypassStatusVinVbypV outDustlterlinlbyploutRese

Page 3 - TableofContents

OperationWARNING:Forsafetyreasons,onlyqualiedpersonnelisallowedtoperformtheoperationproceduresdescribedinthischapter.ModesTheUPShasdifferentoperation

Page 4

SingleSystemwithoutExternalBypassPanelWARNING:Forsafetyreasons,onlyqualiedpersonnelisallowedtoperformtheoperationproceduresdescribedinthischapter.Tur

Page 5 - AboutthisManual

5.GotoYES,UPSintoBypassbyusingtheUP/DOWNnavigationkeysandpressENTER.UseConfirm:UPSintoBypassNO,ABORT→YES,UPSintoBypassPress6.CheckthattheUPSisinbypass

Page 6

PerformaTotalPowerOffNote:InordertocarryoutthisproceduretheloadsupportedbytheUPSmustbeturnedoff.10/100Base-TProbeAP9619NetworkManagementCardEMRese

Page 7 - Overview

PerformaRestartWARNING:OnlyqualiedpersonnelfamiliarwiththeconstructionandtheequipmentmayrestarttheUPS.1.Settheutility/mainsbreakertopositionON.2.Ifyo

Page 8 - DisplayInterface

Note:Theauto-detectiononfrequencyhasbeenimprovedinrmwareversion5.1andhigherforsingleunits(withparallelcapability).Auto-detectiononfrequencyisanoption

Page 9 - MenuTree

4.GotoY es,UPSintoBypassbyusingtheUP/DOWNnavigationkeysandpressENTER.UseConfirm:UPSintoBypassNO,ABORT→YES,UPSintoBypassPress5.FromtheexternalMaintenan

Page 10

PerformaTotalPowerOffNote:InordertocarryoutthisproceduretheloadsupportedbytheUPSmustbeturnedoff.1.CheckthattheloadwhichissupportedbytheUPSisturnedOFF.

Page 11 - Operation

ParallelSystemWARNING:Forsafetyreasons,onlyqualiedpersonnelisallowedtoperformtheoperationproceduresdescribedinthischapter.WARNING:ParallelOperationis

Page 13 - TurnintoNormalOperation

7.FromtheexternalMBP:Turnthebypassswitch(Q3)toposition“|”(ON).8.FromtheexternalMBP:Checkthatthelampindicatoroftheoutputisolationbreaker(H4)atQ4isillum

Page 14 - PerformaTotalPowerOff

11.FromtheexternalMBP:Checkthatalltheoutputlamps(H2)forQ2arenotilluminatedandthatallthebypassinputlamps(H5)atQ5(ifavailable)arenotilluminated.12.Fromt

Page 15 - PerformaRestart

8.FromtheUPS:TurnloadONfromthedisplayofeachUPSviaControl>TurnLoadOn>Yes,TurnLoadOn.9.CheckthattheloadisON.Note:TheUPSsystemisnowreadytosupportth

Page 16

SingleandParallelSystemsTurnLoadoff/onviatheDisplayInterfaceWARNING:Warning:DisconnectingtheUPSoutputtotheloaddoesNOTde-energizetheUPS!Alwaysfollowthe

Page 17

TurnLoadOn–ConnecttheUPSOutputtotheLoadEquipment1.FromtheOverviewScreen,pressENTER.Chrgxxx%Loadxxx%xxxVinxxxVoutxxHzRuntime:xxhrxxminPress2.GotoContro

Page 18

ViewParametersV oltageonallphasesUtility/mainsvoltage(V),bypassvoltage(V),andoutputvoltage(V)foreachphase.CurrentonallphasesUtility/mainscurrent(A),by

Page 19 - ParallelSystem

ViewLoggingViewthe100mostrecentUPSlogevents,andviewtheloggeddetailsoftheevents,suchasdate,timeofoccurrence,andeventnumber.1.FromtheOverviewScreen,pres

Page 20 - 990–2386D-001

ViewStatisticsViewthestatisticsontheoperationmodechanges,theinvertertime,andthedurationofbatteryoperation.1.FromtheOverviewScreen,pressENTER.Chrgxxx%L

Page 21

UsetheDiagsScreenViewtroubleshootinginformation1.FromtheOverviewScreen,pressENTER.Chrgxxx%Loadxxx%xxxVinxxxVoutxxHzRuntime:xxhrxxminPress2.GotoDiagsby

Page 22

CongurationSettingsChangetheClock,theAlarmThresholds,andtheDustFilterStatusDustlterResetdustlterLoadShutdownRuntimeDefaultPar.redund.SystemOverview

Page 23 - SingleandParallelSystems

TableofContentsAboutthisManual...1FindUpdatesto

Page 24 - ViewtheStatusScreens

ClockTheClockmenuchangesthedateandtheclocksettingsandittime-stampseventsintheeventlog.Toavoidinaccuracies,changetheclock-settingatdaylight-savingtime.

Page 25

7.PresstheDOWNnavigationkeytoactivatetheTimeline.UseDate:24-Sep-2010→Time:13:28:00Press8.TheproceduretochangetheTimefeaturesisthesameasdescribedfordat

Page 26 - ViewLogging

4.GotoDustlterbyusingtheUP/DOWNnavigationkeysandpressENTER.UseUPS#:xx↑#ofUPSs:x0xMBPboard:xx→DustfilterOff↓PressNote:Thedefaultsettingofthedustltera

Page 27 - ViewStatistics

Note:Redundancy:Thestateofredundancythatwilltriggeranalarm.Choicesare:•N+0–Thepowerrequirementexceedstheredundancylimit:Redundancyisnotavailable.•N+1–

Page 28 - UsetheDiagsScreen

MaintenanceWARNING:Forsafetyreasons,onlyqualiedpersonnelisallowedtoperformthereplacementproceduresdescribedinthischapter.PartsReplacementDetermineify

Page 29 - Conguration

RemovetheFrontPanel1.Turnthescrewtotherighttotheunlockedposition.2.PullthetopofthefrontpanelawayfromtheUPS.3.Liftthefrontpanelfreeofthetwoslotsatthebo

Page 30 - Sep-2010

InstalltheFrontPanel1.Reinstallthefrontpanelbyinsertingthetwotapsatthebottomofthefrontpanel.(ForJapanesecongurations,youmustrstreinstallthebatteryco

Page 31 - DustFilter

Model:Serial:BATTERYUNITModel:Serial:BATTERYUNITModel:Serial:BATTERYUNITModel:Serial:BATTERYUNITModel:Serial:BATTERYUNITModel:Serial:BATTERYUNITModel:

Page 32 - AlarmThresholds

StoretheBatteriesandtheUPSSystemNote:Thebatterymodulesmustbestoredindoorsandwiththeirprotectivepackagingstillinplace.Note:Storedbatteriesshouldberecha

Page 33

UserInterface(Front)A.NetworkManagementCardwithtemperaturesensor:usedforremotesystemcontrolandmonitoring,e-mailnoticationsetc.Forcongurationanduse,r

Page 34 - Maintenance

Conguration...25Settings...

Page 35 - RemovetheFrontPanel

3.Installthenewcard.4.ReattachthetwoTorxscrews.ReplaceaBatteryModuleGeneralsafetypriortobatterymodulereplacementNote:Whenreplacingbatterymodules,repla

Page 36 - InspecttheDustFilter

4x24kg/4x53lbsRemoveandInstallBatteryLocksIfyoursystemisequippedwithbatterylocks,followthebelowproceduretoremovethebatterylocks.1.RemovetheM6screwatta

Page 37

352mm/(14in)EnclosureColumnAColumnBOldOld Example3NewNewFollowthebelowproceduresifyouneedtochangeoraddabatterymodule,e.g.ifyoureceiveadisplaymessagere

Page 38 - StoretheDustFilter

1.Removepossibleblindplateinfrontofpossibleemptybatteryshelves(savethescrewsforlateruse).2.Installthebatterymoduleinthelowestavailablebay(fouracrossin

Page 39 - 2.Carefullypulloutthecard

TroubleshootingStatusandAlarmMessagesThissectionliststhestatusandalarmmessagesthattheUPSmightdisplay.Themessagesarelistedinalphabeticalorder,andasugge

Page 40 - ReplaceaBatteryModule

DisplayMessageMeaningCorrectiveActionLoadPowerIsAboveAlarmThreshold.Theloadhasexceededtheuser-speciedloadalarmthreshold.Option1:Usethedisplayinterfac

Page 41 - DirectionsforReplacement

DisplayMessageMeaningCorrectiveActionRuntimeIsBelowAlarmThreshold.Thepredictedruntimeislowerthantheuser-speciedminimumruntimealarmthreshold.Eitherthe

Page 42

990–2386D-001MGE™Galaxy™3500Series10-40kV A380/400/415V10-30kV A208/220V43

Page 43

WorldwideCustomerSupportCustomersupportforthisoranyotherproductisavailableatnocharge:•ContacttheCustomerSupportCenterbytelephoneore-mail.Forlocal,coun

Page 44 - Troubleshooting

AboutthisManualThismanualisintendedfortheuseroftheMGE™Galaxy™3500series.Itreferstoimportantsafetywarningsandinstructions,givesanintroductiontothedispl

Page 45 - IfthisdoesnothelpcontactAPC

SafetyWARNING:AllsafetyinstructionsintheSafetySheet(990-2940)mustberead,understoodandfollowedpriortohandling/usingthesystem.Failuretodosocouldresultin

Page 46

OverviewUserInterfaceThefourLEDstotheleftofthedisplayindicatetheoperationalstatusoftheUPS.Thevenavigationkeystotherightareusedtoselectandopenmenuitem

Page 47

DisplayInterfaceTheOverviewScreenisthemainentrancetotheuserfunctionsofthedisplayinterface.TheUP/DOWNnavigationkeystakeyoufromonescreentoanother.TheENT

Page 48 - WorldwideCustomerSupport

MenuTreeCaution:Thedisplayprovidesaccesstomorefunctionsthandescribedinthismanual.ThosefunctionsshouldnotbeaccessedwithouttheassistanceofAPCCustomerSup

Comments to this Manuals

No comments