Summary of Contents

Page 1 - (floor units)

Smart-UPS® VTMaintenance Bypass Panelwith Power Distribution(floor units)10-30kVA208VInstallation and Operation

Page 2

4Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199BProduct OverviewFeaturesAll three floor versions of the Smart-

Page 3 - VT Maintenance Bypass Panel

Product OverviewSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 5Internal componentsAbout the graphics

Page 4

Product Overview6 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Schematic (with panel board)

Page 5 - Contents

Product OverviewSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 7Schematic (without panel board)

Page 6

8Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199BShipping, Receiving, and UnloadingShippingThe floor versions o

Page 7 - Safety warnings

Shipping, Receiving, and UnloadingSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 92. Record any damag

Page 8 - Live maintenance precautions

Shipping, Receiving, and Unloading10 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 4. Attach the wooden

Page 9 - Introduction

Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 11ConsiderationsEnvironmental• The MBP should be kept in a c

Page 10 - Product Overview

12 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199BInstallationOverview• The MBP must be mechanically connected

Page 11 - About the graphics

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 13Removing the front and rear panelsThe fr

Page 13

Installation14 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Front panel removal. 1. Use a T30 Torx scr

Page 14 - Receiving

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 15Rear panel removal. Following installati

Page 15 - Unloading

Installation16 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Mechanically connecting the MBP to the UPS

Page 16 - (on Pallet)

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 173. Remove the side panel from the UPS on

Page 17 - Considerations

Installation18 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 6. Remove the two (2) baying adapters from

Page 18 - Installation

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 198. Roll the MBP into position alongside

Page 19 - Decorative front removal

Installation20 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 10. Insert the six (6) previously removed

Page 20 - Front panel removal

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 21Anchoring the MBP (optional)The MBP (alo

Page 21 - Rear panel removal

Installation22 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Internal cable connectionsFor the convenie

Page 22

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 23Making external cable connectionsExterna

Page 23

Smart-UPS® VT Maintenance Bypass Panel with Power Distribution (floor units)Installation and Operation ManualIMPORTANT SAFETY INSTRUCTIONS- SAVE THESE

Page 24

Installation24 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B UPS connections. 1. The four (4) UPS input

Page 25

InstallationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 25Re-attaching the front and rear panelsFr

Page 26

Installation26 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Rear panel re-attachment. 1. Re-connect th

Page 27 - Anchoring the MBP (optional)

Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 27Installing Panel Board BreakersThis section describes how

Page 28 - Internal cable connections

28 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199BOperationThe MBP with Power Distribution supports four (4) m

Page 29 - Utility connections

OperationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 29Battery back-up operationThe UPS will autom

Page 30 - UPS connections

Operation30 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Bypass operationBypass operation allows the U

Page 31 - Front panel re-attachment

OperationSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 31Returning to normal operationTo return to n

Page 32 - Rear panel re-attachment

32 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199BAppendix A: Changing FusesRemoving fuses1. Remove the decora

Page 33 - WARNING!

Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 33Limited Factory WarrantyThe limited warranty provided by A

Page 34 - Operation

Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B

Page 35 - Static bypass mode

Limited Factory Warranty34 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Drawings, descriptionsAPC warr

Page 36 - Bypass operation

Limited Factory WarrantySmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 35IN NO EVENT SHALL APC, ITS O

Page 37 - Returning to normal operation

36 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B

Page 39 - Limited Factory Warranty

*990-4199B*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of the following ways:• V

Page 40 - Exclusions

ContentsSmart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B iSafety . . . . . . . . . . . . . . . . . . . .

Page 41

ii Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Operation . . . . . . . . . . . . . . . . . . . . .

Page 42 - 36 Smart-UPS

Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 1SafetySAVE THESE INSTRUCTIONSThis manual contains important

Page 43

Safety2 Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B Live maintenance precautionsAPC does NOT recommen

Page 44 - *990-4199B*

Smart-UPS® VT Maintenance Bypass Panel w Power Distribution, 10-30kVA, 208V - 990-4199B 3IntroductionThis manual provides step-by-step instruction o

Comments to this Manuals