990-2822A-001 03/2006
*990-2822A-001*
®
APC Smart-UPS
®
VT ISX Series
and
XR Battery Enclosure
Safety Sheet
IMPORTANT SAFETY
INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This Safety manual provides important safety instructions and general
information on the Smart-UPS
®
VT ISX product series. Illustrations are
representative. Your system may be different from the models shown in this
manual.
Warning
ALL safety instructions in this document shall be read,
understood and followed. Failure to do so could result in
equipment damage, serious injury, or death.
1
Symbol Introduction
Electrical
Hazard
Risk of electric shock.
Warning
Indicates an electrical hazard, which, if not avoided, could
result in injury or death.
Caution
Indicates a hazard, which, if not avoided, could result in
injury or death.
Indicates important information.
Indicates that more information is available on this subject in
a different section of this manual.
See also
Indicates that more information is available on the same
subject in a different manual.
Heavy
Indicates a heavy load that should not be lifted without
assistance.
Smart-UPS® VT UPS Series Safety Sheet
2
Total Power Off Procedure
Set the DC disconnect switch on the Battery Enclosure (if available)
to the OFF position.
If your UPS system contains batteries remove all, or, alternatively,
pull out all batteries to the red disconnect line shown on the battery.
To ensure sufficient stability, do not pull batteries out beyond the red
disconnect line unless completely removing them from the Enclosure.
Set the utility breaker to the OFF or LOCKED-OUT position. If the
UPS has dual mains supply, set both supplies to the OFF or
LOCKED-OUT position.
Set the DC disconnect switch on the XR Battery Enclosure (if
available) to the OFF position.
3
Handling Safety
Mains breaker
Heavy
Do not lift heavy loads without assistance.
<40 lbs
<18 kg.
40-70 lbs
18-32 kg.
70-120 lbs
32-54 kg.
>120 lbs
>54 kg.