APC AP9830 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Smart-UPS RT Accessories
Extended Run Batteries can be easily
added for longer runtimes. Batteries are
also rack or tower convertible for seamless
installation.
SURT48XLBP - Battery pack for Smart-UPS
RT 1000/2000 VA models, 2U in a rack.
SURT192XLBP- Battery pack for Smart-UPS RT
3000/5000/7500/10000 VA models, 3 U in a rack.
Rail Kit enables a Smart-UPS RT or battery
pack to be installed in a 4-Post 19” rack.
SURTRK - Rail kit for Smart-UPS RT
1000/2000 VA models and SURT48XLBP
SURTRK2 - Rail kit for Smart-UPS RT
3000/5000/ 7500/10000 VA models and
SURT192XLBP
APC Network Management Card Ex
(AP9617) Network interface card providing
standards-based remote management of
UPSs. Included in the 5000/7000/10000 models
APC Environmental Monitoring
SmartSlot Card
(AP9612TH) UPS Card
which monitors environmental conditions
in rack, computer room and data center
environments
APC 2-Port Serial Interface Expander
SmartSlot Card
(AP9607) Data protection for
multiple servers on one UPS
APC Smart-Signaling Serial Interface
Expander SmartSlot Card
(AP9623) Data
Protection for Multiple Servers on one UPS
APC Out-of-Band Management
SmartSlot Card
(AP9608) UPS card to
manage UPSs remotely via modem through-
out the network.
APC Relay I/O SmartSlot Card (AP9610)
UPS card to control and monitor power
through a dry-contact interface in rack,
computer room, and data center environments
APC Remote Power-Off Device (AP9830)
Remote Power-Off device that immediately
turns off the output of a connected APC UPS in
computer room and data center environments
APC SmartSlot Expansion Chassis
(AP9600) UPS card chassis that provides an
additional slot for extended management/
monitoring functions.
APC SmartSlot Triple Chassis (AP9604)
UPS card chassis that provides 3 additional
slots for multiple management options.
Accessories
View complete runtime
information at
www.apc.com. Go to
the Smart-UPS RT
product page and click
on Runtime Chart.
Smart-UPS RT 1000 Runtimes (in minutes)
Watts VA SURT1000 + 1 SURT48XLBP + 2 SURT48XLBP + 4 SURT48XLBP
175 250 54m 3h26m 6h17m 12h26m
350 500 27m 1h50m 3h23m 6h45m
700 1000 11m 53m 1h39m 3h20m
Smart-UPS RT 2000 Runtimes (in minutes)
Watts VA SURT2000 + 1 SURT48XLBP + 2 SURT48XLBP + 4 SURT48XLBP
175 250 1hr1m 3h35m 6h22m 12h14m
350 500 32m 1h59m 3h32m 6h50m
700 1000 14m 59m 1h47m 3h29m
1050 1500 8m 38m 1h10m 2h18m
1400 2000 4m 27m 50m 1h41m
Smart-UPS RT 3000 Runtimes (in minutes)
Watts VA SURT3000 + 1 SURT192XLBP + 2 SURT192XLBP + 4 SURT192XLBP
350 500 1h55m 6h31m 11h26m 21h45m
700 1000 55m 3h13m 5h40m 10h49m
1050 1500 34m 2h5m 3h41m 7h4m
1400 2000 24m 1h31m 2h42m 5h12m
1750 2500 18m 1h11m 2h7m 4h5m
2100 3000 14m 58m 1h44m 3h21m
Smart-UPS RT 5000 Runtimes (in minutes)
Watts VA SURT5000 + 1 SURT192XLBP + 2 SURT192XLBP +4 SURT192XLBP
700 1000 48m 2h51m 5h1m 9h35m
1400 2000 21m 1h22m 2h26m 4h42m
1750 2500 16m 1h4m 1h55m 3h42m
2100 3000 13m 52m 1h34m 3h3m
2800 4000 8m 37m 1h8m 2h14m
3500 5000 5m 28m 53m 1h44m
Runtime Chart
Protection
Sine-wave Output provides assurance of com-
patibility with all types of loads.
Lightening and Surge Protection Integrated
Surge Suppression is superior to separate surge
suppressors.
Network-grade Line Conditioning provides
full time EMI/RFI filtering thus preventing data
errors caused by line noise.
Emergency Power Off (EPO) Smart-UPS RT
can be attached to central EPO system for shut-
down in an emergency situation.
Unattended Safe & Graceful Shutdown
prevents possible data corruption by providing
systematic, unattended operating system shut-
down in the event of an extended power outage.
Availability
Zero Transfer Time ensures no interruption of
mission-critical applications when UPS transfers
to/from the batteries.
Wide Input Voltage Range 160-280 VAC input
voltage range at full load allows less time on bat-
tery while preserving battery capacity for blackout
conditions. Input voltage can go as low as 100
VAC, at half load, without using the battery.
Continuous Voltage and Frequency Regulation
Smart-UPS RT provides premium, regulated sine-
wave power for sensitive equipment. Smart-UPS RT
is also generator-set compatible.
Hot Swappable, User Replaceable Batteries
allow continuous operation of the load when bat-
teries are being replaced by the end-user.
Scalable Runtime Unlimited number of match-
ing battery packs can be added to increase run-
time to desired levels.
Built-in Automatic & Manual Bypass ensures
continuous supply of power to the critical loads in
the event of electronic failure, overload condition,
or scheduled maintenance.
Faster Recharge Time ensures battery power is
available more quickly for subsequent power dis-
turbances.
Cold Start provides power-on without input
power being available.
Intelligent Battery Management utilizes micro-
processor to control battery charging and diagnos-
tic testing ensuring maximum battery life.
Economy
Input Power Factor Correction increases
safety and compliance with regional wiring/
electrical standards. Also reduces the utility
power and wiring costs.
Replace Battery lights and alarm sounds when
the UPS battery is nearly dead and must be
replaced (typically within 30 days.)
Battery Charge/Line Voltage displays both pres-
ent battery charge as a percentage of battery
capacity and utility line voltage. Alarm sounds upon
low battery condition.
Off Button turns off the UPS and the load and is
designed to prevent accidental shutdowns.
On/test button turns on the UPS and activates the
UPS self-test and utility line voltage displays.
Load Display shows the power being drawn by the
load so you can avoid exceeding capacity.
On-line LED lights when the UPS is drawing utility
power and performing double conversion to supply
clean power.
On-Battery LED lights, and alarm sounds, when
the UPS is supplying battery power to the load.
Bypass LED lights up when unit is operating in
bypass mode.
Overload LED lights and alarm sounds when the
load connected to the UPS exceeds capacity.
Fault LED lights when unit is experiencing an
internal fault.
Display can be rotated 90° for correct orientation as unit is
shifted from tower to rack configuration.
Adaptability
Rack/Tower Convertible gives Smart-UPS RT a
flexible form factor enabling integration into a
wide variety of end-user environments.
1:1 and 3:1 Combo in a Single Product allows
the same product to be wired to a single-phase or
a three-phase input. This feature is available in
Smart-UPS RT 7500/10000 VA models only.
Multiple Output Voltages 230 VAC nominal out-
put voltage can be programmed for 220 or 240 VAC
operation.
Auto-sensing and Programmable Frequency
Unit automatically provides 50 or 60 Hz. The end-
user can also set output frequency to desired tol-
erance levels.
Flash Programmable Firmware makes the
UPS field-upgradeable.
INFORMATIVE LED DISPLAY PROVIDES STATUS AT A GLANCE
User-friendly, hot-swappable battery replacement
A
B
C
D
E
F
G
H
I
J
Smart-UPS RT 7500 Runtimes (in minutes)
Watts VA SURT7500 + 1 SURT192XLBP + 2 SURT192XLBP + 4 SURT192XLBP
800 1000 1h25m 4h50m 8h30m 16h20m
1600 2000 41m 2h25m 4h15m 8h15m
2400 3000 26m 1h35m 2h50m 5h30m
3200 4000 18m 1h10m 2h5m 4h
4000 5000 13m 54m 1h37m 3h5m
4800 6000 10m 44m 1h20m 2h35m
6000 7500 7m 33m 1h2m 2h
Smart-UPS RT 10000 Runtimes (in minutes)
Watts VA SURT10000 + 1 SURT192XLBP + 2 SURT192XLBP + 4 SURT192XLBP
800 1000 1h25m 4h50m 8h30m 16h20m
1600 2000 41m 2h25m 4h15m 8h15m
2400 3000 26m 1h35m 2h50m 5h30m
3200 4000 18m 1h10m 2h5m 4h
4000 5000 13m 54m 1h37m 3h5m
4800 6000 10m 44m 1h20m 2h35m
6400 8000 6.5m 32m 1h 1h57m
8000 10000 4m 24m 45m 1h28m
Power Management Accessories
A
B
C
D
E
F
G
H
I
J
For more information about APC Solutions visit www.apc.com
For more information about APC Solutions visit www.apc.com
Manageability
Web/SNMP Management Card allows Smart-
UPS RT to be managed, monitored, and config-
ured via an Internet Browser, SNMP Management
Platform (HP-OpenView, Tivoli, CA-Unicenter, and
etc) and Telnet.
PowerChute Software provides comprehensive
management and control of the power environ-
ment surrounding the critical applications.
Built-in SmartSlot houses APC’s accessory
cards, which increase overall system manageability
through timely notification of hazardous conditions.
Terminal Mode Programmability is a menu-
driven interface that allows quick and easy
configuration of the UPS. Ideal for users not using
PowerChute software or a management card.
Alarms and Indicators provide operational
status information of the UPS instantaneously.
APC accessory cards can be inserted into the built-in
SmartSlot to allow monitoring of power conditions The
Smart-UPS RT 5000, 7500, and 10,000 units ship bun-
dled with the Web/SNMP Management Card
Page view 1
1 2

Comments to this Manuals

No comments