Output
Output Power Capacity 210 Watts / 350 VA
Max Configurable Power 210 Watts / 350 VA
Nominal Output Voltage 120V
Waveform Type Stepped approximation to a sinewave
Output Connections
(3) NEMA 5-15R (Battery Backup)
(3) NEMA 5-15R (Surge Protection)
Input
Nominal Input Voltage 120V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
NEMA 5-15P
Cord Length 1.83 meters
Input voltage range for main
operations
98 - 140V
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time 8 hour(s)
Replacement Battery RBC2, RBC2J
RBC™ Quantity 1
Typical Backup Time
at Half Load
20.7 minutes (105 Watts)
Typical Backup Time
at Full Load
5.6 minutes (210 Watts)
Runtime Chart Back
-UPS CS
Energy Use/Efficiency