24-Port 10/100 Ethernet Switch Installation4
2. Choose a location for the unit:
Note: The unit occupies one U-space. A notched hole (or a number, on newer
enclosures) on the vertical rail of the enclosure indicates the middle of a U-space.
a. Insert cage nuts (provided with the enclosure) above and below a notched hole on each
vertical mounting rail in your chosen location.
Warning: Install cage nuts horizontally, with the ears engaging the sides of
the square hole. Do NOT install cage nuts vertically with the ears engaging
the top and bottom of the square hole.
b. Align the mounting holes of the brackets with the installed cage nuts. Insert and tighten
screws.
Applying power
Connect the cord of the power adapter to the power socket on the rear panel of the switch. Connect the
other end of the power cord to an appropriately-protected power source. Check the power indicator on
the front panel to make sure that the switch is receiving power.
Connecting the switch
The RJ-45 ports use either unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable.
For 10 Mbps connections use 100Ω Category 3, Category 4, or Category 5 cable
For 100 Mbps connections use 100Ω Category 5 cable
Note: The length of any twisted-pair connection must not exceed 328 feet (100 meters).
mph0222a