Introduction to the EDA 1200 System
2.2.2 Network Devices
EDA 1200 is a device based system. That is, all the devices are mechanically
and electrically independent. Any connections between nodes are done with
cables. All the nodes use -48 V DC power.
The node environment ratings are:
• Central Office Equipment, -5ºC to +45ºC or +55ºC. This equipment can be
placed outside the central office if the environment is controlled.
• Outside Equipment, -20ºC to +70ºC.
• Hardened Outside Equipment, -40ºC to +75ºC.
Table 2 Node Environment Ratings
Classification
Nodes
Central Office Equipment ECN330, ECN430, EFN324,
EMN120, EPN102, ESN108,
ESN410, EXN104
Outside Equipment EDN312x
Hardened Outside Equipment EDN612
(1)
, EPN210, ESN204g
(2)
,
ESN212
(1) The maximum temperature rating for EDN612 is 45ºC.
(2) The maximum temperature for ESN204g is 70ºC.
The node mounting methods are shown in Table 3 on page 13.
Table 3 Node Mounting Methods
Nodes mounted in 19” or ETSI racks
Nodes mounted on the rods of
rod-based subracks
The EDA 1200 rod mounted devices are mounted in subracks. EDA 1200 has
a variety of dedicated subracks, as well as a general purpose subrack.
13
1/1551-LZA 101 464-V1 Uen C 2009-12-17
Comments to this Manuals