OperationSmart-UPS® X UPSLow Voltage (100-127 V)SMX2000RMLV2USMX2200RMLV2USMX3000RMLV2USMX3000RMLV2UNCHigh Voltage (200-240 V)SMX2200RMHV2USMX3000RMHV
Smart-UPS X-Series 2000/2200/3000 VA Operation8ConfigurationUPS SettingsStart-up SettingsUse the display interface to configure these settings at ini
9Smart-UPS X-Series 2000/2200/3000 VA OperationGeneral SettingsConfigure these settings at any time, using the display interface, APC PowerChute® sof
Smart-UPS X-Series 2000/2200/3000 VA Operation10Date of Last Battery ReplacementDate set at factory Reset this date when the battery module is replac
11Smart-UPS X-Series 2000/2200/3000 VA OperationSwitched Outlet GroupsOverviewThe Switched Outlet Groups can be configured to independently turn off,
Smart-UPS X-Series 2000/2200/3000 VA Operation12Network Management Card Settings These settings are available only on units that have a Network Manag
13Smart-UPS X-Series 2000/2200/3000 VA OperationEmergency Power OffEPO OverviewThe Emergency Power Off (EPO) option is a safety feature that will imm
Smart-UPS X-Series 2000/2200/3000 VA Operation14TroubleshootingProblem and Possible Cause SolutionThe UPS will not turn on or there is no outputThe u
15Smart-UPS X-Series 2000/2200/3000 VA OperationService and SupportServiceIf the unit requires service, do not return it to the dealer. Follow these
Smart-UPS X-Series 2000/2200/3000 VA Operation16Smart-UPS Factory WarrantyLIMITED WARRANTYAmerican Power Conversion (APC) warrants its Smart-UPS (Pro
01/2010990-3651© 2009 APC by Schneider Electric. APC, the APC logo are owned by Schneider Electric Industries S.A.S., American Power Conversion Corpor
ContentsSmart-UPS X-Series 2000/2200/3000 VA OperationiOverview ... 1About the
1Smart-UPS X-Series 2000/2200/3000 VA OperationOverviewAbout the UPSThe APC® by Schneider Electric Smart-UPS® X is a high performance uninterruptible
Smart-UPS X-Series 2000/2200/3000 VA Operation2Rear panelSpecificationsOperating ConditionsThis unit is intended for indoor use only. Select a locati
3Smart-UPS X-Series 2000/2200/3000 VA OperationInstallationUPSFor UPS installation information, see the Smart-UPS X 2000-3000 VA Quick-Start that is
Smart-UPS X-Series 2000/2200/3000 VA Operation4OperationConnect Equipment to the UPSNote: The UPS will charge to 90% capacity in the first three hour
5Smart-UPS X-Series 2000/2200/3000 VA OperationDisplay InterfaceOverviewUsing the display interfaceUse the UP and DOWN to scroll through the main men
Smart-UPS X-Series 2000/2200/3000 VA Operation6Load meter (kWh) xLast transfer to battery power information x xBattery charge and estimated run time
7Smart-UPS X-Series 2000/2200/3000 VA OperationAboutGeneral information about the UPS, including: model numbers, output voltage setting, serial numbe