Switched Rack PDUs
Mounting
U-space
Nominal
Power
Nominal
Voltage
Input Plug
Type
Vertical, 0U 100 – 120 NAM 15 A 1.4 kW NEMA 5-15P (16) 5-15 3.0 m AP7931
Vertical, 0U 120 NAM, LAM 20 A 1.9 kW NEMA L5-20P (24) 5-20 3.0 m AP7930
Vertical, 0U 100 Japan 20 A 1.9 kW NEMA L5-20P (24) 5-15 3.0 m AP7930J
Vertical, 0U 120 NAM, LAM 30 A 2.9 kW NEMA L5-30P (24) 5-20 3.0 m AP7932
Vertical, 0U 100 Japan 30 A 3.0 kW NEMA L5-30P (24) 5-15 3.0 m AP7932J
Horizontal, 1U 100 – 120 NAM, LAM 15 A 1.4 kW NEMA 5-15P (8) 5-15 3.6 m AP7900
Horizontal, 1U 100 – 120 NAM 20 A 1.9 kW NEMA L5-20P (8) 5-20 3.6 m AP7901
Horizontal, 2U 120 NAM 30 A 2.9 kW NEMA L5-30P (16) 5-20 3.6 m AP7902
Horizontal, 2U 100 Japan 32 A 3.0 kW NEMA L5-30P (16) 5-15 3.6 m AP7902J
Vertical, 0U 230 EMEA, APJ, 10 A 2.3 kW IEC C14 (16) C13 3.0 m AP7950
GCN
Vertical, 0U 100 – 240 NAM, LAM 20 A 3.3 kW NEMA L6-20P (7) C13 (1) C19 3.0 m AP8958NA3
Vertical, 0U 100 – 240 Worldwide 16 A 3.3 kW IEC 320 C20 (7) C13 (1) C19 Inlet AP8958
Vertical, 0U 230 EMEA, APJ, 16 A 3.7 kW IEC 309 16 A (7) C13 (1) C19 3.0 m AP8958EU3
LAM, GCN
Vertical, 0U 100 – 240 NAM, LAM 20 A 3.3 kW NEMA L6-20P (21) C13 (3) C19 3.0 m AP8959NA3
Vertical, 0U 100 – 240 Worldwide 16 A 3.3 kW IEC 320 C20 (21) C13 (3) C19 Inlet AP8959
Vertical, 0U 230 EMEA, APJ, 16 A 3.7 kW IEC 309 16 A (21) C13 (3) C19 3.0 m AP8959EU3
LAM, GCN
Vertical, 0U 200 – 240 NAM, LAM 30 A 5.0 kW NEMA L6-30P (21) C13 (3) C19 3.0 m AP8941
Vertical, 0U 220 – 240 EMEA, APJ 32 A 7.4 kW IEC 309 32 A (21) C13 (3) C19 3.0 m AP8953
LAM, GCN
Horizontal, 1U 208 – 230 Worldwide 10/15 A 2.5 kW IEC 320 C14 (8) C13 2.0 m AP7920
Horizontal, 1U 208 – 230 Worldwide 16 A 3.3 kW IEC 320 C20 (8) C13 2.4 m AP7921
Horizontal, 2U 200 – 240 NAM 30 A 5.0 kW NEMA L6-30P (16) C13 3.6 m AP7911A
Horizontal, 2U 230 EMEA, APJ, 32 A 7.4 kW IEC 309 32 A (16) C13 3.6 m AP7922
LAM, GCN
100 – 120 V Input
Voltage
Region
Input
Circuit
Output
Receptacles
200 – 240 V Input
Cord
Length
APC SKU
Switched Rack PDUs provide advanced load monitoring
combined with remote on/off switching control of
individual outlets for power cycling, delayed power
sequencing, and outlet use management.
What is metered on AP8800, AP8900,
and AP8600 Series Rack PDUs?
> Device: power and energy
> Phase:current*, power, and voltage
> Internal circuit breaker (bank): current*
> Outlet: current, power, energy (AP8600 Series only)
Why do we meter?
> Device: Rack level capacity change, planning,
and efficiency calculations
> Phase: Balance loads between phases to protect
against tripping upstream branch circuit breakers
> Internal circuit breaker (bank): Protect against
tripping internal circuit breakers
> Outlet: Detailed capacity change, equipment
efficiency, and trends
*AP7000 series monitors current per phase and breaker only.