APC MGETM GALAXYTM 6000 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
Server
Internetworking and Network Protection
SYSTEM SPEED
DESKTOP AND SERVER AVAILABILITY
SUPPORT STAFF ALWAYS AVAILABLE
CRITICAL NEEDS
Smart-UPS XL
Performance power protection for servers, and voice and data networks.
Possibility for runtime extensions
Line-Interactive Technology
Perfect sine-wave output
Hot-swappable batteries
Serial port or serial, USB and SNMP (optional), serial & USB port
SNMP (optional & standard from 5kVA)
System protected shutdown
LED status indicator and audible alarm
PowerChute Business Edition Software
Part numbers - size and weight
VA Code XxWxD (mm) Kg
15000 SURT15KRMXLI 533x432x773 247,73
20000 SURT20KRMXLI 533x432x773 247,73
Smart-UPS RT 15 / 20
Electric protection to tall performances with extension of
battery for small data centers, voice/data networks, medical
labs & light industrial applications
Double-conversion on-line technology
Reduced dimensions, only 12U in rack
Input / output: 1/1 standard configuration 3/1 or 3/3
modifiable from the customer (user configurable)
Perfect sine-wave output
Configurations tower and rack. Convertible form factor
Tower or rack form factor
With automatic and manual bypass in standard
PowerChute Network Shudown Software
Smart-UPS RT 15000 20000
Technical specifications
Power (VA) 15000 20000
Power (W) 12000 16000
Input voltage for main operations (V) 170 - 275 (single phase) or 277 - 476 (3-phase)
Output voltage (V) 220-230-240 (single phase) or 380-400-415 (3-phase)
Output voltage distorsion < 5 % with full load
Crest factor 3 : 1
Typical Backup Time at Full Load 75
Smart-UPS 750 1000 1500 2200 3000 5000
Technical specifications
Power (VA) 750 1000 1500 2200 3000 5000
Power (W) 500 670 980 1980 2700 4000
In. vol. range for main operat. (V) 160 - 286
Output voltage (V) 230 (configurable 220, 230 or 240)
Output voltage distortion < 5% with full load
Crest factor 5 : 1
Typical Backup Time at H.L. (*) 16 21 24 24 14 27
Typical Backup Time at F.L. (*) 56 7 769
(*) for Tower models
Part numbers – Tower UPS - size and weight
VA Code HxWxD (mm) Kg
750 SUA750I 157X137X358 13
1000 SUA1000I 216X170X439 19
1500 SUA1500I 216X170X439 24
2200 SUA220I 423X196X546 51
3000 SUA3000I 423X196X546 56
Part numbers – RackMount UPS - size and weight
VA Code HxWxD (mm) Kg
750
SUA750RMI1U 44x432x660 22
SUA750RMI2U 89x432x457 22
1000
SUA1000RMI1U 44x432x660 22
SUA1000RMI2U 89x432x457 28
1500 SUA1500RMI2U 89x432x457 29
2200 SUA2200RMI2U 89x483x660 44
3000 SUA3000RMI2U 89x483x660 44
5000 SUA5000RMI5U 222x483x660 98
Smart-UPS
Performance power protection for servers, and voice and data networks.
Line-Interactive Technology
Perfect sine-wave output
Hot-swappable batteries
Serial port or serial, USB and SNMP
(optional), serial & USB port
SNMP (optional & standard from 5kVA)
System protected shutdown
LED status indicator and audible alarm
PowerChute Business Edition Software
Smart-UPS RT
Performance power protection with scalable runtime for space-constrained server rooms,
and voice data networks, medical labs & light industrial applications
Double-conversion on-line technology
Serial port
LED status indicator and audible alarm
Perfect sine-wave output
Possibility for runtime extensions
Hardwire Input & Output from 3 kVA Tower models
SNMP (optional & standard from 8 kVA Tower and from 5 kVA Rackmount)
PowerChute Business Edition Software
UPS rack -Part numbers – size and weight
VA Code HxWxD (mm) Kg
1000 SURT1000RMXLI 85x432x483 23
2000 SURT2000RMXLI 85x432x483 25
3000 SURTD3000RMXLI 130x432x660 55
5000 SURTD5000RMXLI 130x432x660 55
6000 SURT6000RMXLI 130x432x660 55
8000 SURT8000RMXLI 263x432x663 111
10000 SURT10000RMXLI 263x432x663 111
Smart-UPS RT 1000 2000 3000 5000 6000 8000 10000
Technical specifications
Power (VA) 1000 2000 3000 5000 6000 8000 10000
Power (W) 700 1400 2100 3500 4200 6400 8000
In. vol. range for main operat. (V) 160 - 280 160-280/380-415
Output voltage (V) 230 (configurable 220, 230 or 240)
Output voltage distortion < 5% with full load
Crest factor 3 : 1
Typical Backup Time at H. L. 24 15 34 15 16 18 13
Typical Backup Time at F. L. 10 4 14 5 5 6 4
UPS tower -Part numbers – size and weight
VA Code HxWxD (mm) Kg
1000 SURT1000XLI 432x85x483 23
2000 SURT2000XLI 432x85x483 25
3000 SURT3000XLI-ET (*) 432x130x660 55
5000 SURTD5000XLI-ET (*) 432x130x660 55
6000 SURT6000XLI-ET 432x130x660 55
8000 SURT8000XLI 432x263x663 111
10000 SURT10000XLI 432x263x663 111
(*) non -ET models available with web/SNMP, enviromental & dry contac
card included BUT no hardwire output
Smart-UPS SC
Power protection for entry-level servers, voice and data networks
and Point of sales (POS)
Boost and Trim Automatic Voltage Regulation (AVR)
Phone line/RJ45 modem/fax/ADSL/network protection
Hot- swappable batteries
Serial port or serial and UPS ports
LED status indicator and audible alarm
PowerChute Business Edition Software
Smart-UPS CS 420 620 1000 1500
Technical specifications
Power (VA) 420 620 1000 1500
Power (W) 260 390 600 865
Input voltage (V) 160-286 175-295
Range for main operations (V) 230
Typical Backup Time at Half Load 14 16 20 21
Typical Backup Time at Full Load 5578
UPS size HxWxD (mm) 168x119x368 89x432x463
UPS weight (kg) 9131621
Part numbers
Tower version SC420I SC620I SC1000I SC1500I
2U rackmount/Tower version aviable aviable SC1000I SC1500I