Technical Specifications
The following table contains the specifications for the H10.
Item Specification
INPUT
Input Voltage Range for Opera-
tion (on utility)
92V - 145V
Nominal Voltage 120 Vac
Allowable Input Frequency for
Operation (on utility)
47 - 63 Hz
Rated Input Current 12 Amps
Input Circuit Breaker Rating 15 Amps
OUTPUT
Number of Outlets 12 (all outlets are surge pro-
tected, conditioned, and regu-
lated)
Outlet type NEMA 5-15R
Rated VA Capacity 1000VA
Rated Watt Capacity (continuous) 1000 Watts
Rated Output Current 12 Amps
SURGE PROTECTION
Let-Through Voltage Rating <40 Volts
Peak Surge Current (NM + CM) 230KA
Data Line Protection Jacks (split-
ter)
Single-line 2-wire phoneline
protection for phone, modem, or
fax.
Coax
MISCELLANEOUS
DC Trigger Two 3.5mm mini-jack plugs
(5-30V)
EMI/RFI 40-100dB at 100KHz-30MHz
Total Surge Joules 4720