Back-UPS BR900G-RS Installation and Operation
3
Connect the Equipment
Battery Backup and Surge Protected outlets
When the Back-UPS is receiving input power, the Surge
Protection only outlets and the Battery Backup with
Surge Protection outlets will supply power to connected
equipment. During a power outage or other AC
problems, only the Battery Backup outlets receive
power for a limited time from the Back-UPS.
Connect equipment such as printers, FAX machines,
scanners, or other peripherals that do not need battery
backup power to the Surge Protection Only outlets.
These outlets provide full time protection from surges
even if the Back-UPS is switched off.
Master and Controlled outlets
To conserve electricity, when the device connected to
Master Outlet goes into Sleep or Standby mode, or turns
off, the Controlled by Master device(s) will shut down
as well, saving electricity.
Connect a master device, such as a desktop computer or
audio/visual receiver to the Master outlet. Connect
peripheral devices such as a printer, speakers, or a
scanner to the Controlled by Master outlets.
USB and Serial Data port To use PowerChute software, connect a USB cable, to the USB or serial port.
Telephone Cable Surge-
protected ports
Connect one end of a DSL/Modem/FAX/Phone cable to a telephone wall outlet and the other end to the
IN port on the Back-UPS. Connect one end of a DSL/Modem/FAX/Phone cable to a modem, FAX
machine or telephone and the other end to the
OUT port on the Back-UPS.
Surge Protection outlet,
Controlled by Master outlet
This outlet provides surge protection during a power outage. This outlet will disconnect from AC
power during a power outage, or in the event that the Master outlet goes into Sleep mode.
Surge Protection outlets These outlets provide full-time protection for connected equipment from power surges when the Back-
UPS is turned on or off. The Surge Protection outlets do not provide battery backup to connected
equipment. Connect a printer, scanner or other noncritical devices that do not require battery backup
protection.
AC Power Cable Use this cable to connect the Back-UPS to AC power.
Battery Backup outlets with
Surge Protection
These outlets provide battery backup power to connected equipment for a limited period of time during
power outages and voltage fluctuations. The Battery Backup + Surge Protection outlets provide battery
power to connected equipment only when the Back-UPS is turned on.
Connect critical equipment such as a computer, computer monitor, modem or other data sensitive
devices to these outlets. Do not connect aquarium equipment, laser printers, paper shredders, sump
pumps, or fans to these outlets as the modified sine wave output of the Back-UPS may cause these
devices to experience a decrease in performance. Do not connect surge protectors or extension cords to
these outlets.
Battery Backup, Controlled
by Master outlet with Surge
Protection
This outlet provides surge protection for the connected device. To conserve energy the Controlled by
Master outlets will disconnect from AC power whenever the device plugged into the MASTER outlet
is turned off or goes into Standby or Hibernation mode.
Master outlet Connect the master device to this outlet, in most cases, this will be the main computer.
In addition to providing battery backup power and surge protection, this outlet will signal the
Controlled by Master outlets to disconnect from AC power when the master device is either turned off
or goes into Standby or Hibernation mode.
Gigabit Ethernet
surge-protected ports
Use an Ethernet cable to connect a modem or router to the IN port, and a computer to the OUT port.
Circuit breaker Press the circuit breaker reset button after an overload condition or a short circuit has occurred
causing the circuit breaker to trip. This action can be taken when the Back-UPS is operating on
utility or battery power.
bu214a
Tel Out
Tel In
USB &
Serial
Battery
Backup
Surge
Only
MASTER
Controlled by MASTER
Controlled by MASTER