Customise your power
protection solution with
UPS Accessories* from APC
Reboot hung servers
via Web, SNMP, or Telnet
From your Network Management Station you
may use the 10Base-T Ethernet Web/SNMP
Management Card (AP9606) and/or Token
Ring (AP9603) SNMP Card. Perform remote
UPS shutdown, reboot, and other management
and diagnostic functions.
Integrate smoke or halon alarms,
telephone switches and other dry
contact closures
Add security to your UPS system with the
Relay I/O Card (AP9610).
Monitor temperature, humidity and
rack security
Smoke alarms and halon alarms can also be
monitored with the Environmental
Monitoring Card (AP9612TH) through the
PowerChute plus, PowerNet SNMP or the
Out-of-band Management Card interface.
The alarm switch kit (AP9513) is designed to
monitor and notify users (when used in con-
junction with AP9612TH and the NetShelter
®
rack enclosure) if the NetShelter door has
been breached.
Extended UPS monitoring
The Isolated Serial Extension Cable (ISEC) is
designed to provide bulletproof monitoring of
an APC UPS for extended distances up to100
meters (AP9825).
Reboot hung servers and networking
equipment remotely via modem
The Out-of-band Management Card (AP9608)
provides complete UPS information, paging on
power problems and remote safe reboot of
servers via user supplied modem.
Safely shutdown up to three servers
The 2-Port Interface Expander Card (AP9607)
provides two additional ports to facilitate
graceful system shutdown via dependable
hardwire connections and allows advanced
UPS management. The unit is ideal for “server
farms” or multiple operating system
environments, since all three servers can be
running different OSs.
Shutdown multiple servers from one UPS
Connect up to 8 completely OS-independent
servers to a single UPS with Share-UPS
(AP9207) 8-Port interface expander (15 servers
with 2 Share-UPS). Share-UPS integrates with
PowerChute plus software. Each server runs its
own copy of PowerChute plus software, for
monitoring and power management of the UPS.
Integrate multiple accessories
The Triple Expansion Chassis (AP9604) is an
external, 1U, 19” rack-mountable device that
allows integration of additional UPS slot
accessories with a Smart-UPS, Matrix, or
Symmetra Power Array. Triple Expansion
Chassis can be used in a rack environment
or as a stand-alone device that allows you to
add up to three (3) slot cards to UPSs that
have an existing slot already in use.
MasterSwitch
remote reboot device
The MasterSwitch (AP9210i) network power
controller can easily reboot remote servers,
internetworking equipment, or banks of
modems to prevent on-site service calls. The
perfect complement to your High Availability
solution, MasterSwitch gives you power
distribution and complete, remote control of
eight independent power channels to put an
end to the frustration of locked-up servers
and wasted management time.
Remote Power-off Device
The APC Remote Power-off Device (RPO)
allows data center managers to turn off APC
UPS output with a remote switch. When used
in conjunction with an Emergency Power-Off
(EPO) system, the RPO can turn off equipment
in an emergency. (AP9830)
Isolated Serial
Extension Cable
APC MasterSwitch
Power Controller
Triple
Expansion Chassis
Web/SNMP
Management Card
(*Note: APC accessory cards are designed to
work with APC UPS products that have a
SmartSlot bay. The SU420INET and SU620INET
products do not have a SmartSlot bay.)
Management Peripherals for Smart-UPS
Out-of-band
Management
Card (AP9608)
Relay I/O Card
(AP9610)
2-port
Interface
Expander
Card (AP9607)
Environmental
Monitoring Card
(AP9612TH)
Share-UPS8 port
interface expander
APC Remote
Power-off Device
For more Turkish information, visit the web site at
www.APCturkey.com