APC AP88XX User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
990-3864E
13. User names can be defined using the Config.ini file, but by default
password keys are no longer included. Transferring an unedited Config.ini
file in the old format (with password keys) can cause unintended user name/
password pairs unless the user name field is removed from the file.
14. When SNMPv3 access is enabled, disabling SNMPv1 access by clearing the
"Enable SNMPv1 access" check box has no effect.
15. If the manual upload of the data log is repeated at 90-second intervals,
the third upload attempt will fail.
16. In the Config.ini file, the [SystemPreference] key EventLogDisplay shows:
- 0 instead of Disabled and
- 1 instead of Enabled.
17. In SNMP browsers, UDP ports are not reported correctly and all TCP
ports except the Web port are not shown.
18. The NMC supports six SNMP trap receivers, but only four can be
configured to receive event notifications.
19. When using Mozilla Firefox, access using HTTP port 6000 is blocked.
Microsoft Internet Explorer 6 allows access using HTTP port 6000.
20. In the Web interface, the Primary and Secondary RADIUS servers accept
invalid IP address values.
21. In the CLI, the Primary and Secondary RADIUS server commands append the
previous server secret to the end of the new server secret.
22. In the Config.ini: the SystemUserManager username keys return strange
values when the value is greater than 10 characters in length.
23. In the Config.ini: the SystemDateTime Server keys return strange values
when long strings are applied.
24. Domain Name parameter displays result as "Success" for Invalid value in
the CLI.
25. The usernames for Admin, Device and Read-only users allow longer strings
than the 64-character limit in the Config.ini file.
26. The User Link Display name configuration exceeds 20 characters when
using a Config.ini file.
27. The Quick Links Display name configuration only allows 6 characters in the
web text box.
28. The snmp mib2 udp/tcp connection tables are incorrect.
29. There are different Date Formats on the NMC General/About page.
30. The CLI does not process HOME or END keys properly.
31. The CLI command history buffer continuously wraps around, instead of
stopping at the end/beginning
32. In the Config.ini: SystemLinks, LinkName and LinkDisplay fields truncate
values which are too long.
Page 3