APC Silcon
60-80kW 208/480V UPS
User Guide
Copyright ©2000 APC Denmark ApS
Information in this document is subject to
change without notice and does not represent
a commitment on the part of the vendor
Page view 0
1 2 3 4 5 6 ... 33 34

Summary of Contents

Page 1 - User Guide

APC Silcon60-80kW 208/480V UPSUser Guide Copyright ©2000 APC Denmark ApS Information in this document is subject tochange without notice and does n

Page 2

10 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Stop/Start UPS and Operating the External Service Bypass

Page 3 -

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 11 NOTICE!

Page 4 - Introduction

12 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Stop/Start UPS and Operating the External Service Bypass 2.6 Operating the External Service

Page 5 - 2.2 Start UPS (from stand-by)

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 13ActionSteps 1-4 apply to all the par

Page 6

14 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Stop/Start UPS and Operating the External Service Bypass 2.6.2 Switching the Parallel System

Page 7

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 15Action1. Check that the output switc

Page 8

16 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Stop/Start UPS and Operating the External Service Bypass 2.7 Isolating one UPS in a Parallel

Page 9 - **System OFF**

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 17 NOTICE!

Page 10 - 990-4035

18 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Operation 3.0 Operation The display unit will read parameters, alarms/messages and measured v

Page 11

Operation 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 19 3.2 Display of Measured Values To read measurements, press one or two keys simulta

Page 12

2 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Thank You Thank you for chosing APC Silcon. Please read this User Guide thoroughly prior to in

Page 13

20 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Operation 3.3 Using the Remote Display The remote display is an inactive unit that is unable

Page 14

Parameter Settings 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 214.0 Parameter Settings Below tables show operating parameters programmable

Page 15

22 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035Parameter Settings4.1 Programming Keys4.2 Switching to Bypass OperationProgramming ExampleScroll

Page 16

Parameter Settings990-4035User Guide APC Silcon 60-80kW 208V/480V UPS 23To return to normal operationFollow same procedure to program other parameter

Page 17

24 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035Alarms and Events5.0 Alarms and Events Alarms are indicated by the red lamp (above the left hand

Page 18 - Operation

Alarms and Events990-4035User Guide APC Silcon 60-80kW 208V/480V UPS 255.3 Possible AlarmsNOTICE!

Page 19

26 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035Alarms and Events19. **Q001 off** UPS input switch position –20. High temperature of isolation t

Page 20

Alarms and Events990-4035User Guide APC Silcon 60-80kW 208V/480V UPS 275.4 Rectifying Alarm MessagesFollowing actions may rectify alarm:• Check local

Page 21 - Parameter Settings

28 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035Alarms and Events5.5 Parallel Operation AlarmsThe parallel operation alarm message is: Communic

Page 22

Maintenance & Testing990-4035User Guide APC Silcon 60-80kW 208V/480V UPS 296.0 Maintenance & TestingUPS maintenance should be carried out by

Page 23

990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 3 Contents: 1.0 Introduction 41.1 Display Unit 42.0 Stop/Start UP

Page 24 - Alarms and Events

30 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035Maintenance & Testing

Page 25

Warranty990-4035User Guide APC Silcon 60-80kW 208V/480V UPS 317.0 Warranty7.1 APC Silcon UPS Limited Factory WarrantyAPC warrants that the unit, when

Page 26

32 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035How to Contact APC8.0 How to Contact APC APC Corporate 132 Fairgrounds Road West Kingston, RI 0

Page 27

990-4035User Guide APC Silcon 60-80kW 208V/480V UPS 339.0

Page 28

34 User Guide APC Silcon 60-80kW 208V/480V UPS990-4035

Page 29 - Maintenance & Testing

4 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Introduction 1.0 Introduction This UPS system is designed to offer reliable and problem-free p

Page 30

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 52.0 Stop/Start UPS and Operating the

Page 31 - Warranty

6 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Stop/Start UPS and Operating the External Service Bypass 2.3 Stop UPS (for complete power dow

Page 32 - How to Contact APC

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 7 The UPS is now isolated. Maintenance

Page 33

8 User Guide APC Silcon 60-80kW 208V/480V UPS 990-4035 Stop/Start UPS and Operating the External Service Bypass System start-up now completed. NOTIC

Page 34

Stop/Start UPS and Operating the External Service Bypass 990-4035 User Guide APC Silcon 60-80kW 208V/480V UPS 9 2.5 Operating the External Service B