Page view 11
12
12
12
12
12
12
12
12
12
12
12
12
Honda MCHP, Model MCHP1.2D(P), Type UCFJ
Honda MCHP (UCFJ) Heating Capacities –
Natural Gas & Propane
Model
Natural Gas Model 1.2D
Propane Model 1.2DP
Honda MCHP -
MCHP Mode
Input (Btu/hr) 0-3,300’ 18,420
Thermal Output (Btu/hr) 0-3,300’ 12,300
Power Output (kW) 1.2
Voltage (V) 240
Current (A) 5
Noise Level - dB(A) 1m 47
MCHP Steady State Ef ciency 89%
Honda MCHP -
Back-Up Mode
Input (Btu/hr) 0-3,300’ 18,500-26,000
Thermal Output (Btu/hr) 0-3,300’ 12,000-17,000
Electrical Output (kW) 0 - 1.8*
Voltage (V) 120
Current (A) 0-15
Noise Level - dB(A) 1m 47
MCHP Steady State Ef ciency 89%
Honda MCHP (UCFJ) -
Grid Boost Mode
Input (Btu/hr) 0-3,300’ 26,000
Thermal Output (Btu/hr) 0-3,300’ 17,000
Electrical Output (kW) 1.8
Voltage (V) 240
Current (A) 7.5
Noise Level - dB(A) 1m 47
MCHP Steady State Ef ciency 89%
Maximum Venting Lengths Reduce Vent length 5 feet for each 90° elbow
Venting Length (ft.) – Honda MCHP (2”) 110 ft.
* Maximum power available to connected loads is 1,700 Watts due to 100 Watt power
consumption of load balancing transformer.
freewatt
®
Transfer Switch (Model FTS-1.8)
freewatt
®
Transfer Switch
Electrical Speci cation
Manufacturer ECR Int’l
Model No. FTS-1.8
Max. Watts 1,800
Max. Single-Pole Circuits 4
Max. Double-Pole Circuits 0
Max. current@ 120VAC 15A
Max. current@240VAC 7.5A
Minimum Wire Gauge 14AWG
Conduit Trade-Size (diameter) ½”
PERFORMANCE DATA