NETWORK AND SERVER
Symmetra
®
LX
High performance, redundant power protection with scalable power and runtime for space-constrained server rooms and
voice and data networks
Range: 4-16 kVA N+1 Redundant Rack/Tower Convertible 13U-19U, 4-16kVA N+1 Redundant Extended Run Tower
Network Manageable
Monitor and control the UPS and access environmental
information remotely via included PowerChute
®
soft-
®
soft-
®
ware or APCs Network Management Card with tem-
perature monitoring (included in all models above 3kVA).
Modular Design
Provides fast serviceability and reduced maintenance
requirements via self-diagnosing, hot-swappable, and
field-replaceable modules.
Configurable for N+1 Internal Redundancy
Provides high availability through redundancy by
allowing configuration with one more Power Module
than is necessary to support the connected load.
Scalable Power Capacity
Reduces UPS over-sizing costs today by allowing
quick upgrades later.
Manageable External Batteries
Reduces preventative maintenance service needs by
monitoring the health and status of the external batter-
ies and their expected runtime.
Shippable with Modules Installed
Enables pre-installation UPS staging and testing and
faster installation.
LCD Display
Manage the UPS locally through a text-based display
that allows quick diagnosis via stored alarm condi-
tions and events.
Automatic Internal Bypass
Supplies utility power to the connected loads in the
event of a UPS overload condition or fault.
Frequency and Voltage Regulation
Gives higher application availability by correcting poor
frequency and voltage conditions without using the
battery.
Engineered to deliver the highest level of business continuity pos-
sible, the Symmetra
®
LX uses a modular, redundant architecture
®
LX uses a modular, redundant architecture
®
that can scale power and runtime as demand increases or when
higher levels of availability are required. With built-in network man-
ageability, and rack-optimized and tower models available from
4-16 kVA N+1 redundant, the online Symmetra LX is the choice
to protect high-performance IT and Telecom equipment in busi-
ness-critical server and network rooms. A flexible rack/stack design
offers unmatched runtime and power capacity in space constrained
environments. Symmetra LX allows incredibly fast upgrades and
maintenance with virtually all of its parts contained in field-swap-
pable components. These include hot-swappable, user-replaceable
power, battery, and intelligence modules, management cards, LCD
display, fans, and external battery frames. Additionally the wiring
tray, frame electronics, receptacles, and casters can be swapped
in minutes if necessary. Symmetra LX achieves industry-leading
footprint or U-space needed in an equipment rack, increased speed
and ease of deployment, and reduced repair time.