DATA CENTERS AND FACILITIES
Silcon
®
Performance power protection with scalable runtime for data centers and
facilities
Range: 40 to 80kW in 208V, 10 to 500kW in 480V and 60 to 480 kW in 400V
The APC Silcon
®
Series has the load capacity to serve a broad range of electrical
®
Series has the load capacity to serve a broad range of electrical
®
equip-
ment, from mainframe computers to large corporation-wide installations, production
lines, electronic control systems and telecommunication equipment. Up to nine Silcon
units can be paralleled to serve special demands for power upgrading or redundancy.
Input Power Factor Correction
Eliminates the need for an external phase-com-
pensation unit and minimizes installation costs
by enabling the use of smaller generators and
cabling.
Fully-rated Power kVA Equals kW
Reduces cost by eliminating the need for an over-
sized UPS for Power Factor Corrected (PFC) loads.
Network Manageable
Provides remote management of the UPS over
the network.
Generator Compatible
Ensures clean, uninterrupted power to protected
equipment when generator power is used.
Manageable External Batteries
Reduces preventative maintenance service needs
by monitoring the health and status of the external
batteries and their expected runtime.
Parallel-capacity Capable
Increases total power capacity by using multiple
UPSs simultaneously.
Parallel-redundant Capable
Power the connected equipment with multiple
UPSs to increase system redundancy.
Symmetra
®
MW
High performance, redundant power protection with scalable power and run-
time for data centers and facilities
Range: 400kW to 1.6MW
Symmetra
®
MW redefines high-power UPS technology as a modular, fault-tolerant
®
MW redefines high-power UPS technology as a modular, fault-tolerant
®
UPS in the 400-1600 kilowatt range. Ideal for large data centers, complete buildings,
healthcare and other critical facility protection requirements, the Symmetra MW can
be scaled for rigorous and changing electrical demands. Symmetra MW provides
increased availability through internal N+1 configurability, predictive failure notifica-
tion and multi-module paralleling features. Setting a new standard for low cost of
ownership Symmetra MW delivers best-in-class efficiency and a reduction in rating
of electrical infrastructure- wires, transformers and generators. Slide-in/out power
modules, manageable external batteries and self-diagnosing features greatly reduce
mean time to repair. Combined with a wide range of line-up and match options
Symmetra MW provides a customizable system in a standardized design for any large
on-demand network-critical physical infrastructure.
Modular Design
Provides fast serviceability and reduced main-
tenance requirements via self-diagnosing,
field-replaceable modules.
Scalable Power Capacity
Reduces UPS over-sizing costs today by allowing quick
upgrades later.
Fully-rated Power kVA Equals kW
Reduces cost by eliminating the need for an oversized
UPS for Power Factor Corrected (PFC) loads.
Input Power Factor Correction
Eliminates the need for an external phase-compensation
unit and minimizes installation costs by enabling the use
of smaller generators and cabling.
Configurable for N+1 Internal Redundancy
Provides high availabilty through redundancy by allow-
ing configuration with one more Power Module than is
necessary to support the connected load.
Generator Compatible
Ensures clean, uninterrupted power to protected
equip-
ment when generator power is used.
Power Modules Connected in Parallel
Enhances availability by allowing immediate, seamless
recovery from isolated module failures.
Battery Modules Connected in Parallel
Delivers higher availability through redundant batteries.
LCD Display
Provides schematic overview of critical data for guided
operation and troubleshooting on color LCD touchscreen.