Installation and Operation Back-UPS 1250, 1300, 15006
Power-Saving LCD screen
The display interface can be configured to remain continuously illuminated or to extinguish after a
period of inactivity to save electricity.
1. Continuous Illumination mode: Press and hold
DISPLAY button for two seconds. The display
will illuminate and the
Back-UPS will beep to confirm Continuous Illumination mode is activated.
2. Power-Saving mode: Press and hold
DISPLAY button for two seconds. The display will extinguish
and the Back-UPS will beep to confirm Power-Saving mode is activated. While in Power-
Saving mode, the display will illuminate if a button is pressed, it will extinguish after 60 seconds
of inactivity.
Back-UPS sensitivity settings
The Back-UPS detects and reacts to line voltage distortions by transferring to battery backup power to
protect connected equipment. In situations where either the Back-UPS or the connected equipment is too
sensitive for the input voltage level it is necessary to adjust the transfer voltage.
1. Connect the Back-UPS to a utility power source. Be sure the Back-UPS is turned off.
2. Press and hold the
POWER button for six seconds. The load capacity bar will flash on and off, to
indicate the Back-UPS is in Program mode.
3. Press
the POWER button again to scroll through the menu options. The Back-UPS will beep to
confirm the selection.
Refer to the table for an explanation of the transfer voltage sensitivity levels.
Front panel buttons and display
Use the buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS.
Generator Sensitivity Default Sensitive Loads
Low sensitivity Medium sensitivity (Default) High sensitivity
78-142 Vac 88-139 Vac 88-136 Vac
Use this setting with equipment that is
less sensitive to fluctuations in voltage
or waveform distortions.
Use this setting under normal operating
conditions.
Use this setting when connected
equipment is sensitive to any minor
fluctuations in voltage or waveform
distortions.
Front panel
MUTE button
POWER button
DISPLAY button
Display
On Line: The Back-UPS is supplying conditioned utility power to connected equipment.
Power-Saving Function: The MASTER and CONTROLLED outlets are enabled. The power-saving feature is
active when the master device goes into Standby or Hibernation mode.
bu109b