3.7 Enclosure Management
“Enclosure management” function allows managing enclosure information including
“SES config”, “Hardware monitor”, “S.M.A.R.T.” and “UPS” functions. For the
enclosure management, there are many sensors for different purposes, such as
temperature sensors, voltage sensors, hard disks, fan sensors, power sensors, and
LED status. And due to the hardware characteristics are different among these sensors,
for different sensors, they have different polling intervals. Below is the detail about
polling time intervals:
1. Temperature sensors: 1 minute.
2. Voltage sensors: 1 minute.
3. Hard disk sensors: 10 minutes.
4. Fan sensor: 10 seconds, when there are continuous 3 times of error, controller
sends ERROR event log.
5. Power sensor: 10 seconds, when there are continuous 3 times of error, controller
sends ERROR event log.
6. LED status: 10 seconds.