3.7.2 Hardware Monitor
Enter “Hardware monitor” function to view the information of current voltage,
temperature, power supply, and fan status.
If “Auto shutdown” has been checked, the system will shutdown automatically when
voltage or temperature is out of the normal range. For better data protection, please
check “Auto Shutdown”.
For better protection and to avoid single short period of high temperature triggering
Auto shutdown, the iSCSI RAID subsystem use multiple condition judgments for Auto
shutdown, below is the detail of when the Auto shutdown will be triggered.
1. There are 3 sensors placed on the controller for temperature checking, on core
processor, on PCI-X bridge, and on daughter board. The iSCSI RAID subsystem
will check each sensor every 30 seconds. When one of these sensors is over the
high temperature value for continuous 3 minutes, the Auto shutdown will be
triggered immediately.
2. The core processor temperature limit is 85°C. The PCI-X bridge temperature limit
is 80°C. The daughter board temperature limit is 80°C.
3. If the high temperature situation doesn’t last for 3 minutes, the subsystem will not
do auto shutdown.