18
How To Determine On-Battery Run Time
UPS battery life differs based on usage and environment. It is recommended that the
battery/batteries be changed once every three years.
On-Battery Run Time (Minutes)
Load (VA) Load (watts) SU1400
100 60 133
200 122 91
300 185 67
400 249 50
500 315 39
600 382 31
700 450 24
800 522 19
900 595 16
1000 670 13
1200 809 9
1330 900 7
1400 1050 6
Run Time (Minutes) with External Battery Packs (SU24RMXLBP2U)
# of battery packs:
Load (VA)
1 2 3 4 5 6 7 8 9 10
700
70 130 210 280 350 420 490 560 640 720
1200
32 65 100 150 190 230 270 310 350 400
1400
23 47 70 100 140 170 200 240 270 300