APC Back UPS 1400 VA User Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
22
1. Face the front of the UPS and, using both hands, insert each
index finger behind the lip of the curved section of the front
bezel and pull towards you. The front bezel will unsnap.
2. Set the bezel aside.
3. Use a screwdriver or coin to remove the two (2) battery
door screws and open the door.
4. Take out the white cord, which is tucked into the space
above the battery connector . Grasp the cord and pull
firmly towards you to disconnect the battery.
5. Pull the battery out of the UPS by pulling the clear label ,
not the white cord. The white cord is connected to the
battery leads, not the body of the battery. (The battery
consists of a string of four batteries.)
6. Return the battery to APC for recycling. (Refer to How To
Contact APC, page 4, for information.)
7. Supporting the new battery on the bottom, align it with the
battery door opening and slide it into the compartment.
8. Remove the tape on the new battery connector to expose the
cable’s gray connector.
9. Locate the UPS battery connector which is to the right of
the battery compartment and recessed. Connect the battery
cable connector to the UPS connector. Press firmly to
ensure that the connection is tight. You will hear a “snap”
when the connector is properly seated.
10. Replace the two (2) screws and washers removed in step 3.
11. Tuck the white battery cable cord neatly into the space
above the UPS connector.
12. Hold the front panel bezel with the cutout section on the
right. Align the tabs on the side of the bezel with the slots
on the front of the UPS and firmly snap it into place.