1.4 Features
CellGuard™ Intelligent Battery Management
The UPS provides visual and audible indications of the batterys status including low battery and replace
battery conditions.
The UPS exercises the battery during its self-test, and will detect a weak battery before it is put into service.
The UPS normally performs a self-test at power up and every 14 days thereafter. Self-tests can also be con-
ducted manually with the on/off button at any time. See section 5.2.
The UPS features user-replaceable hot-swappable batteries. Batteries can be replaced without having to re-
move power from the loads or send the UPS in for service.
Power Management Software
This UPS offers advanced features when connected via the computer interface to a device using power man-
agement software.
Telephone Line and Network Surge Protection
This UPS provides advanced single telephone line or 10Base-T network surge suppression through the
modular connectors on the back panel. See section 4.
2. Safety
CAUTION!
n To reduce the risk of electric shock in conditions where load equipment grounding cannot be verified,
disconnect the UPS from the AC power outlet before installing a computer interface or accessory slot
signal cable. Reconnect the power cord only after all signaling connections are made.
n Connect the UPS to a two-pole, three-wire grounding AC power outlet. The receptacle must be con-
nected to appropriate branch protection (fuse or circuit breaker). Connection to any other type of re-
ceptacle may result in a shock hazard and violate local electrical codes.
n The UPS has an internal energy source (the battery).
TT
TT
T
he output mahe output ma
he output mahe output ma
he output ma
y be enery be ener
y be enery be ener
y be ener
gizgiz
gizgiz
giz
ed wed w
ed wed w
ed w
hen the unit ishen the unit is
hen the unit ishen the unit is
hen the unit is
not connected to an not connected to an
not connected to an not connected to an
not connected to an
AA
AA
A
C poC po
C poC po
C po
ww
ww
w
er outlet.er outlet.
er outlet.er outlet.
er outlet.
n To deenergize the outputs of the UPS:
1. If the UPS is on press the on/off button to switch the UPS off.
2. Disconnect the UPS from the AC power outlet.
3. To deenergize the UPS completely, disconnect the battery. See section 10.
Never install telephone wiring during a lightning storm.
n Use of this equipment in life support applications where failure of this equipment can reasonably be
expected to cause the failure of the life support equipment or to significantly effect its safety or effec-
tiveness is not recommended.