Page 1 - SymmetraPX100kW208V

SymmetraPX100kW208VOptionalModularPDU(600:208V,480:208V,208:208V,208VTransformerless)Installation

Page 2

RecommendedBoltandLugSizesCableTerminalBoltDiameterCableLugTypeCrimpingtoolCT-720CrimpingDie:80%rated100%rated80%rated100%ratedMainsinputM10LCA4/0-12H

Page 3 - TableofContents

ACOutput208V:208V480V:208V600V:208VNotransformerConnectiontype4-wire(3PH+N+G)or3wire(3PH+G)Outputvoltage3x208/120VNominaloutputcurrent(A)278278278278P

Page 4

RecommendedConductorSizesCaution:Allwiringmustcomplywithallapplicablenationaland/orlocalelectricalcodes.ConductorsizinginthismanualisbasedonTable310-1

Page 5

FullLoadHeatLossatNominalMainsWARNING:ThisisaClassAUPSproduct.Inadomesticenvironment,thisproductmaycauseradiointerference,inwhichcase,theusermayberequ

Page 6

InstallationProcedureNote:Onlysystemsinstalledonaraisedfloormustusebottomcableentry.1.Mechanicalassembly.2.Prepareforcables(notshown).3.Connectpowercab

Page 7 - SAVETHESEINSTRUCTIONS

InstallationswithPDUwithTransformerNote:Forbottomcableentrysystems,makesuretofollow“InstalltheInternalConductorsforBottomEntrySystemsinInstallationswi

Page 8 - Specifications

DualUtilitySystemTopCableEntrySystemXR Battery EnclosureXR Battery EnclosureXR Battery EnclosureXR Battery EnclosureUPS11111111444436External communic

Page 9 - •Useonlycopperconductors

InstallationswithPDUwithoutTransformerSingleUtilitySystemTopCableEntrySystemXR Battery EnclosureXR Battery EnclosureXR Battery EnclosureXR Battery Enc

Page 10 - RecommendedBoltandLugSizes

DualUtilitySystemTopCableEntrySystemXR Battery EnclosureXR Battery EnclosureXR Battery EnclosureXR Battery EnclosureUPS11111111444436External communic

Page 11 - InrushCurrents

MechanicalAssemblyRe-arrangetheSidePanelsWARNING:Forsafetyreasons,theUPSsidepanelsmustalwaysbeinstalledontherightsideofthePDUeventhoughitisplacedupaga

Page 13 - Batteries

InstalltheSidePanels1.Setthebaseofthepanelatanangleandpushthepanelin.2.Lockthesidepanelswiththeredkey.InstalltheInternalConductorsforBottomEntrySystem

Page 14 - InstallationProcedure

4.ConnecttheN,L1,L2,L3conductorstothebottomterminals.PerformEquipotentialBondingNote:Itmightbenecessarytomovesomeoftheequipotentialbondingwirestofityou

Page 15 - SingleUtilitySystem

2222223.Useascrewdrivertolowerthefourlevelingfeet.344.Usea13/17mmwrenchtoadjustthelevelingfeet.WARNING:Donotmovetheenclosureafterthelevelingfeethavebe

Page 16 - DualUtilitySystem

PrepareforCablesInstallationswithoutPDU1.OpenthereardooroftheUPS.2.Removeallfourcovers,startingfromthetop,bylooseningthetwoscrewsineachcover.Notetheor

Page 17

TopCableEntryMakeHolesintheTopoftheUPS1.Removethecoverplates.RearoftheUPS12.Drillasmanyholesasnecessaryinthesolidplateandinstalltheconduits.Re-install

Page 18

InstallationswithPDUwithTransformer1.OpenthefrontdoorofthePDU.2.Removetheuppercover.UseaPhillipsscrewdrivertoremovethecaptivepanelfasteners.3.Inbottom

Page 19 - MechanicalAssembly

TopCableEntryMakeHolesintheTopCoverofthePDU1.Removethededicatedcoverplateforpowercables.FrontofthePDU12.Drillholesintheplateforconduits.Re-installthep

Page 20 - 990–3659C-001

BottomCableEntryMakeHolesintheBottomoftheSideCar1.Removethededicatedcoverplate.FrontoftheSideCar12.Drillholesintheplateforconduitsandre-installtheplat

Page 21 - RearoftheSystem

InstallationswithPDUwithoutTransformer1.Fortopentrysystems,removethebottomcoverontherearsideofthePDUandthrowawayorrecyclethecoilofconductors.Rearofthe

Page 22

TopCableEntryMakeHolesintheTopCoverofthePDU1.Removethededicatedcoverplateforpowercables.FrontofthePDU12.Drillholesintheplateforconduits.Re-installthep

Page 23 - PrepareforCables

TableofContentsIMPORTANTSAFETYINSTRUCTIONS–SAVETHESEINSTRUCTIONS...

Page 24

BottomCableEntryMakeHolesintheBottomofthePDU1.RemovethebottomtwoplatesontherearsideofthePDU.RearofthePDU112.Removethededicatedcoverplateforpowercables

Page 25 - 1.OpenthefrontdoorofthePDU

4.Removethededicatedcoverplateforsubfeedbreakercables.RearofthePDU45.Drillholesintheplateforconduits.Re-installtheplatewiththeconduitsinstalled.Rearof

Page 26 - TopCableEntry

PowerCablesAPCrecommendsusinga45ºcablelug(notprovided)forconnectionofpowercablestotheUPS.Ifyouusestraightcablelugs,installabusbarsafetybracketbetweene

Page 27

ConnectPowerConductorsinInstallationswithoutPDUCaution:Ensureclockwisephaserotationandneutrallocation.Thepowerterminalboltdiameteris10mm.Therequiredto

Page 28 - 2.OpenthefrontdoorofthePDU

ConnectPowerConductorsinInstallationswithPDUwithTransformerCaution:Ensureclockwisephaserotationandneutrallocationofthepowerterminalbolt.Therequiredtor

Page 29

3.TakethecablesthatarepreinstalledintheSideCarandroutethemthroughtheleftorrightside(dependingonconfiguration)intothePDU.4.Routetheconductors(inputcondu

Page 30 - BottomCableEntry

ConnectPowerConductorsinInstallationswithPDUwithoutTransformer—TopCableEntryCaution:Ensureclockwisephaserotationandneutrallocationofthepowerterminalbo

Page 31

ConnectPowerConductorsinInstallationswithPDUwithoutTransformer—BottomCableEntryCaution:Ensureclockwisephaserotationandneutrallocationofthepowertermina

Page 32 - PowerCables

ConnectPowerConductorsbetweentheUPSandthePDU(ApplicabletoallSystemswithPDU)1.OpenthereardoorsofthePDUandtheUPS.2.RemovethecoverfromthePDUtogetaccessto

Page 33

ConnectOutputCablestotheSubfeedBreakerCaution:Ensureclockwisephaserotationandneutrallocationofthepowerterminalbolt.Wiresizeandtorquearespecifiedonbreak

Page 34

PrepareforCables...17InstallationswithoutPDU...

Page 35

InstallandConnectOutputCablestothePowerDistributionModuleNote:PowerDistributionModulesandbackplanesarecolour-coded:blackfor120/208Vandgreyfor240/415V.

Page 36

BatteryCablesInstalltheAPCBatterySolutionTheSymmetraPX100kWUPScanmonitoruptofourAPCXRBatteryEnclosures.Caution:Thesystemacceptsupto300kcmilcables.Thep

Page 37 - Q1 = single (default)

RearoftheXRBatteryEnclosure12RearoftheXRBatteryEnclosurewiththeplatesremoved34.ConnecttheBAT+,BAT-,andCT(midpoint)cablesbetweentheXRBatteryEnclosures.

Page 38

6.ConnecttheequipmentgroundingcableintheXRBatteryEnclosurethatisfarthestfromtheUPS.RouteitthrougheachXRBatteryEnclosuretotheUPSthroughtheside,top,orbo

Page 39 - L1,L2,L3

1.Beforerunningthecablesthroughtheside,loosenthethreeboltsonthecablereliefnexttotheXRBatteryEnclosure.2.RoutethebatterycablestotheUPSthroughtheholesin

Page 40

EmergencyPowerOff(EPO)SwitchNote:EPOswitchwiringmustcomplywithlocalandnationalCodewiringrules.ReviewtheplannedEPOinstallationandoperationwiththelocalA

Page 41 - BatteryCables

EPOswitchwiringdiagramNote:ThesystemisconfiguredforinstallationswithoutEPO.InsystemswithN/OEPO,connecttheEPOtoJ25pin1and2.InsystemswithN/CEPO,removethe

Page 42

CommunicationWiresConnectNetworkCommunicationWire1.Thenetworkcommunicationwire(supplied)hasbeenpre-connectedtotheUPSandislocatedonthetopoftheenclosure

Page 43

ConnectCommunicationWiresinInstallationswithoutPDUMaintenance Bypass PanelUPSXR BatteryEnclosureXR BatteryEnclosureXR BatteryEnclosureXR BatteryEnclos

Page 44 - Battery Enclosure

MaintenanceBypassPanelInterfaceWARNING:Ensurethatthewiresareproperlyretainedandkeptawayfromhigh-voltagelinesandbreakers.Make contact closure connectio

Page 45 - EmergencyPowerOff(EPO)Switch

InstalltheFrontAnchoringBracket...49InstalltheTopAssemblyBracket...

Page 46 - EPOswitchwiringdiagram

ConnectCommunicationWiresinInstallationswithPDUPDUUPSXR BatteryEnclosureXR BatteryEnclosureXR BatteryEnclosure0P31990P41231234566566213FrontJ7J8J9J11.

Page 47 - CommunicationWires

InstallSeismicOptionReplacetheSidePanelLock1.Removethesidepanelfromtheendofrowenclosures.12.Useascrewdrivertopressonthetapthatsecuresthelocktothesidep

Page 48

4.Putthetwolockpartstogether.5.Looselytightenthescrews.546.Placethesidepanelatanangleatthebottomoftheframe.67.Pushthetopofthesidepanelinplace.746Symme

Page 49

8.Holdthesidepanelwithonehand.9.Takethelockassemblyandguidethetopthroughtheholeinthesidepanel.10.Liftthelockassemblyinplace.11.Ensurethattheupperandlo

Page 50

InstalltheRearAnchoringBrackets1.Securetheflooranchoringbrackettothefloorusingflooranchoringbolts(notsupplied).UseM12strengthclass8.8or1/2ingrade5steelbo

Page 51 - InstallSeismicOption

InstalltheFrontAnchoringBracket1.Securethefrontanchoringbrackettotheenclosure.12.Securethefrontanchoringbrackettothefloorusingflooranchoringbolts(notsup

Page 52 - 5.Looselytightenthescrews

InstalltheDoorHingeLockNote:Thisprocedureisonlyapplicablefor600mmand750mmwideenclosures.Requiredparts:•Twodoorhingelocks•Fourscrews1.Withonehandslidet

Page 53

InstalltheBatteryLocksRequiredpartsforeachbatteryrow:•Ninebatterylocks•45screws1.Placethebatterylockbelowthebatteryrow.2.Securethelockbythefiveprovided

Page 56 - InstalltheDoorHingeLock

ivSymmetraPX100kW208V990–3659C-001

Page 57 - InstalltheBatteryLocks

WorldwideCustomerSupportCustomersupportforthisoranyotherproductisavailableatnocharge:•ContacttheCustomerSupportCenterbytelephoneore-mail.Forlocal,coun

Page 58

IMPORTANTSAFETYINSTRUCTIONS–SAVETHESEINSTRUCTIONSWARNING:ALLsafetyinstructionsintheSafetysheet(990-2984)mustberead,understood,andfollowedwheninstallin

Page 59

SpecificationsCaution:Allelectricalpowerandpowercontrolwiringmustbeinstalledbyaqualifiedelectrician,andmustcomplywithlocalandnationalregulationsformaxim

Page 60 - WorldwideCustomerSupport

RecommendedCurrentRatingofFeederCircuitBreakersCaution:Toreducetheriskoffire,connectonlytoacircuitprovidedwith(seebelow)amperesmaximumbranchcircuitover

Comments to this Manuals