The MPIO setup instructions are the following:
1. Create RG/VD, and then attach LUN.
2. Add the first “Target Portal” on Microsoft iSCSI initiator.
3. Add the second “Target Portal” on Microsoft iSCSI initiator.
4. Logon.
5. Enable “Enable multi-path” checkbox. Then click “Advanced…”.
6. Select the first “Source IP” and “Target Portal” to iSCSI data port 1. Then
click “OK”.
7. Logon again.
8. Enable “Enable multi-path” checkbox. Then click “Advanced…”.
9. Select the second “Source IP” and “Target Portal” to iSCSI data port 2. Then
click “OK”.
10. iSCSI device is connected. Click “Details”.
11. Click “Device” tab, then click “Advanced”.
12. Click “MPIO” tab, select “Load Balance Policy” to “Round Robin”.
13. Click “Apply”.
14. Run “Device Manage” in Windows. Make sure MPIO device is available.
15. Done.
The MC/S setup instructions are in the following:
1. Create RG/VD, and then attach LUN.
2. Add the first “Target Portal” on Microsoft iSCSI initiator, For MC/S, there is
only ONE “Target Portals” in the “Discovery” tab.
3. Logon.
4. Then click “Advanced…”.
5.
Select the first “Source IP” and “Target Portal” to iSCSI data port 1. Then
click “OK”.
6. After connected, click “Details”, then in the Session” tab, click
“Connections”.
7. Choose “Round Robin” in “Load Balance Policy”.
8. “Add” Source Portal for the iSCSI data port 2.
9. Select the second “Source IP” and “Target Portal” to iSCSI data port 2. Then
select “OK”.
10. Done.