23InfraStruXure Central Installation Manual
E2017 Timer Fail
Timer refresh failure.
E2018 Prog Timer
Programmable interval timer error.
E2019 Parity Error
Parity error.
E201A SIO Err
SIO failure.
E201B Kybd Controller
Keyboard controller failure.
E201C SMI Init
System management interrupt (SMI) initialization failure.
E201D Shutdown Test
BIOS shutdown test failure.
E201E POST Mem Test
BIOS POST memory test failure.
E201F DRAC Config
Dell remote access controller (DRAC) configuration failure.
E2020 CPU Config
CPU configuration failure.
E2021 Memory Population
Incorrect memory configuration. Memory population order
incorrect.
E2022 POST Fail
General failure after video.
E2110 MBE Crd # DIMM ## &
##
One of the DIMMs in the set implicated by "## & ##" has had a
memory multi-bit error (MBE). If no memory card is present,
the "Crd #" string is left out of the message.
E2111 SBE Log Disable Crd #
DIMM ##
The system BIOS has disabled memory single-bit error (SBE)
logging, and will not resume logging further SBEs until the
system is rebooted. "##" represents the DIMM implicated by the
BIOS. If no memory riser card is present, the "Crd #" string is
left out of the message.
E2112 Mem Spare Crd # DIMM
##
The system BIOS has spared the memory because it has
determined that the memory had too many errors. "## & ##"
represents the DIMM pair implicated by the BIOS. If no
memory card is present, the "Crd #" string is left out of the
message.
E2113 Mem Mirror Crd # DIMM
## & ##
The system BIOS has disabled memory mirroring because it has
determined that one half of the mirror has had too many errors.
"## & ##" represents the DIMM pair implicated by the BIOS. If
no memory card is present, the "Crd #" string is left out of the
message.
E2118 Fatal NB Mem CRC
One of the connections in the Fully Buffered DIMM (FBD)
memory subsystem link on the Northbound side has failed.
E2119 Fatal SB Mem CRC
One of the connections in the FBD memory subsystem link on
the Southbound side has failed.
I1910 Intrusion
System cover has been removed.
I1911 >3 ERRs Chk Log
LCD overflow message.
A maximum of three error messages can display sequentially on
the LCD. The fourth message displays as the standard overflow
message.
I1912 SEL Full
System Event Log is full of events, and is unable to log any
more events.
W1228 ROMB Batt < 24hr
Warns predictively that the RAID battery has less than 24 hours
of charge left.