Configuration – Parts Replacement
Smart-UPS® VT ISX 20-30 kVA, 208/220/480V Operation 21
How to remove Battery Modules
Follow the below procedures if you need to change or add a Battery Module, e.g. if you receive a display
message reporting a bad battery, or if you need to add batteries for increased runtime.
Battery Module APC Part No.
1 Battery Module (4 batteries) SYBT4
Network Management Card and Temperature/humidity Sensor APC Part No.
Network Management Card with temperature sensor AP9619
Temperature/humidity Sensor AP9512THBLK
Use two people to lift components weighing between 40 – 70 lb / 18 – 32 kg.
Note
When removing Battery Modules, start from the highest level and work down.