APC J15BLK Datasheet

Browse online or download Datasheet for Uninterruptible power supplies (UPSs) APC J15BLK. APC J Type 1500VA Desktop UPS - 1500VA 865W - 3.9 Minute(s) Full-load User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Models: J10, J10BLK, J15

Model J15 ShownJ Type Power Conditioner with Battery Backup Owner’s ManualModels: J10, J10BLK, J15, and J15BLK

Page 2

1-2 Proven Expertise… Proven Reliability From corporate data centers to home offices, APC is regarded as an innovator, designer and manufacturer of hi

Page 3 - Safety Information

1-3 Unit Power Capacity The J10 Power Conditioner is rated for 600 watts (continuous), and the J15 is rated for 865 watts (continuous). They have bee

Page 4

1-4 Isolated Noise Filter Banks Both models reduce electromagnetic and radio frequency interference (EMI/RFI) that, when severe enough, can negativel

Page 5 - Warnings, Cautions and Notes

1-5 Front and Rear Panels The following sections describe the controls and indicators on the front and rear panels. Front Panel Controls and Indicato

Page 6

1-6 STATUS Push Button When pressed, provides unit status for: Input and Output Voltage, Input and Output Frequency , Telephone and Internet

Page 7 - Table of Contents

1-7LINE OK Status Indicator When lit, input voltage from the utility is within acceptable range. If not lit, the Automatic Voltage Regulation circuit

Page 8

1-8DELAYED 2 Status IndicatorWhen lit (blue), conditioned power is being supplied to equipment connected to the rear-panel outlets marked Delayed 2.14

Page 9 - Introduction

1-9Rear Panel Connectors, Indicator, and Circuit BreakerThe rear panel connectors for the J10 and J15 Power Conditioner are detailed in Figure 3. The

Page 10 - Package Contents

1-10AC-Powered Outlets - The J10 and J15 Power Conditioner provides for connection of up to twelve (12) components. The outlets are arranged according

Page 11 - Features

1-11Surge Protected COAX/RF ConnectorsThe surge protection feature prevents surges traveling over coaxial data lines from damaging the system. Connect

Page 13 - Front and Rear Panels

1-12Input Power ConnectorProvides for connection of one end of the supplied AC power cord to the J10 or J15 Input Power Connector. Connect the other e

Page 14

1-13DATA PORT Jack (USB)Enables the J10 and J15 to communicate with the included PowerChute Personal Edition software. If the unit is also protecting

Page 16 - DELAYED 2 Status Indicator

2-1 Chapter 2 Installation This chapter contains the following sections: • Removing the Battery Pack • Placing the Unit • Inserting and Connecting th

Page 17

2-2 removed first as described above. Lift each unit carefully by firmly grasping both sides of unit in the middle. Failure to comply may result in per

Page 18

2-3 Powering On and Connecting Equipment 1. Power on the unit.2. Connect the equipment.3. Connect the data line cables.4. Power on the connected equi

Page 19

2-4 Figure 6. Model Identification Screen DELAYED OUTLET1: ON; DELAYED OUTLET2: OFF screen (Figure 7) — shows that power is available to the device

Page 20

2-5 SELFTEST IS ON; ON-LINE SELFTEST screen (Figure 8) — shows that an On-Line Selftest is active. Figure 8. SELFTEST IS ON; ON-LINE SELFTEST Scr

Page 21

2-6 SELFTEST RESULT; SELFTEST HAS PASSED screen (Figure 10) — shows that the Selftest ran successfully to completion. If the message “ TEST HAS FA

Page 22

2-7 Status and Informational Screens The following sections describe the status and informational screens. Status Screens The most important status s

Page 23 - Installation

iSafety Information1. Read this manual - Read all of the safety and operating instructions beforeinstalling and operating this device.2. Keep this ma

Page 24

2-8 SYSTEM LOAD: <XXXW; LOAD: <XXX% This screen is shown in Figure 12. The J10 and J15 can also display the value (load) of the connected equip

Page 25 - Performing the System Test

2-9 displayed. APC recommends you set the “default” screen showing the “ ESTIMATED RUNTIME and FUEL ” display (Figure 13). Informational Screens Th

Page 26

2-10Firmware Version: XXXXXXX ScreenThis screen, shown in Figure 15, provides information about which version of the firmware is loaded in to the unit.

Page 27

2-11Phone Number and Technical Support Internet Address This screen, shown in Figure 17, provides the world-wide telephone number for APC, as well as

Page 28

2-12INPUT FREQUENCY; OUTPUT FREQUENCY ScreenThis screen, shown in Figure 18, shows the actual input utility voltage frequency, as well as the actual v

Page 29 - Status Screens

2-13Setting Up the J10 or J15 Using the Front-Panel ControlsUsing the front panel SETUP and Arrow Up/Down push buttons, you can configure or turn on/of

Page 30

2-14AUDIBLE ALARM Setting — when set to ON (Figure 19), provides an audible tone to alert the user to changing power and unit conditions. In the OFF s

Page 31 - Informational Screens

2-15LOW Sensitivity — should be used when the UPS frequently goes to battery (even though the utility voltage appears normal).Figure 20. SENSITIVITY

Page 32

2-16GO TO BATTERY IF > XXXV Setting — lets you set a high voltage threshold for the unit, which will force it to switch to power from the battery o

Page 33 - Support or Customer Service

2-17OUTLET DELAY1 and OUTLET DELAY2 Setting (not shown) screens — lets you to set a defined time delay (0 to 10 seconds) for when the unit provides pow

Page 34 - Connecting the Components

ii Safety Information (continued)16. Overloading - Do not overload the wall outlet where this device is beingconnected. Do not overload this devic

Page 35 - Front-Panel Controls

2-18BATREPDATE: XX/XX/XX Setting (Figure 25) — lets you input the exact date a replacement Battery Pack was installed in the unit. First, use the Up/D

Page 36

2-19DO RUNTIME CAL: screen (Figure 27) — lets you manually initiate a Runtime Calculation test to calibrate the internal measurements, which should re

Page 37

2-20Figure 29. DISPLY-BEEP TEST: Screen (all indicators/fields lit)SCREEN SAVER: ON/OFF screen (Figure 30) — lets you force the unit to alternate a me

Page 38

2-21RESET TO DEFAULT: YES/NO Setting (Figure 31) — lets you force the unit to reset all previous settings to the factory default values. Simply advan

Page 40

3-1 Chapter 3 Warranty Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship fo

Page 41

3-2 EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE U

Page 42

4-1 Chapter 4 Contact Information Technical Support General Information Internet Address:http://www.apc.com/supportEmail Support:support.apcc.comToll

Page 44

A-1 Specifications A Technical Specifications The table on the following pages contains the technical specifications for the Model J15 and J10 J Type Po

Page 45 - Warranty

iiiRegistration Verification ConfirmationBy registering your purchase now, it guarantees you will receive all the information and special offers you

Page 46

A-2 Models J15, J15BLK J10, J10BLK INPUTVoltage Range for Operation on Utility90V – 144V SameNominal Voltage 120 Vac SameAllowable Frequency for O

Page 47 - Contact Information

A-3 Battery Life 2-5 Years(Depending on use, environment,and temperature)SameEstimated Battery Runtime (Actual runtimes are determined by load, bat-t

Page 48

A-4 WARRANTYWarranty 2 yearsincludingbatterySame

Page 49 - Technical Specifications

B-1 Troubleshooting B Troubleshooting Problems This appendix describes possible causes and solutions for the following problems: 1. Unit will not tur

Page 50

B-2 Possible Cause: No power or insufficient power available at the wall outlet. Solution: Ensure the wall outlet has good power by using a voltmete

Page 51

B-3 “Replace Battery” LED is indicated. Possible Cause: Battery is nearing the end of its useful life. Solution: If the unit’s warranty is more tha

Page 52

B-4 990-2457 Copyright © 2005 American Power ConversionAll rights reserved. The APC AV logo is a registered trademarkof American Power Conversion. A

Page 54

v Table of Contents Safety Information iProtect Your Investment iiiIntroduction 1-1 Proven Expertise… Proven Reliability 1-2Safety Precautions 1-2Pac

Page 56

1-1 Chapter 1 Introduction Congratulations on your purchase of APC’s Model J10 or J15 Power Conditioner with Battery Backup (Model J15 shown in Figur

Comments to this Manuals