APC IN ROW RD ACRD101 User's Guide Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
56InRow RD 100-Series and InRow RD 200-Series User’s Guide
Customizing. You must customize the file before you export it.
1. Use a text editor to customize the file.
Section headings, keywords, and pre-defined values are not case-sensitive, but string values
that you define are case-sensitive.
Use adjacent quotation marks to indicate no value. For example,
LinkURL1="" indicates that
the URL is intentionally undefined.
Enclose in quotation marks any values that contain leading or trailing spaces or are already
enclosed in quotation marks.
To export scheduled events, configure the values directly in the .ini file.
To export a system time with the greatest accuracy, if the receiving cooling units can access a
Network Time Protocol server, configure
enabled for NTPEnable:
NTPEnable=enabled
Alternatively, reduce transmission time by exporting the [SystemDate/Time] section as a
separate .ini file.
To add comments, start each comment line with a semicolon (
;).
2. Copy the customized file to another file name in the same folder:
The file name can have up to 64 characters and must have the .ini suffix.
Retain the original customized file for future use. The file that you retain is the only record
of your comments.
Transferring the file to a single cooling unit. To transfer the .ini file to another cooling unit, do
either of the following:
From the Web interface of the receiving cooling unit, select the Administration tab, General on
the top menu bar, and User Config File on the left navigation menu. Enter the full path of the file,
or use Browse.
Use any file transfer protocol supported by cooling units, i.e., FTP, FTP Client, SCP, or TFTP).
The following example uses FTP:
a. From the folder containing the copy of the customized .ini file, use FTP to log in to the
cooling unit to which you are exporting the .ini file:
ftp> open ip_address
b. Export the copy of the customized .ini file to the root directory of the receiving cooling
unit:
ftp> put filename.ini
Exporting the file to multiple cooling units. To export the .ini file to multiple cooling units:
Use FTP or SCP, but write a script that incorporates and repeats the steps used for exporting the
file to a single cooling unit.
Use a batch processing file and the APC .ini file utility.
To create the batch file and use the utility, see Release Notes: ini File Utility, version
1.0 on the Utility CD.
Page view 62