Solving Problems
96-00290-001 Rev. A1 DataDirect Networks StorageScaler 2460 User Guide | 25
4. Pull the two release handles (Figure 29) and carefully slide the controller out of the bay.
Release
Handles
Figure 29. Release Handles on I/O Controller
5. Gently slide a new controller into the bay until the black handles engage. Then press
the handles until the I/O canister latches into place.
6. Connect the cables according to
the notes you made when you removed the old
controller.
7. If necessary, power on your equipment in t
his order:
a) Power on the SS2460 enclosure.
b) Then, power on the host system.
4.3 Removing a Disk Drive (or Blank Drive Carrier)
NOTE :
For disk drive installation instructions, see Section2.4.
Important Safety Precautions
Before you remove a disk drive, read these important notes:
To avoid data loss, stop all I/O activity on the di
sk drive before removing it. Removing
a disk drive during I/O activity could also hang the host system.
•Do NOT attempt to remove more than one disk drive or blank drive carrier at a time.
Damage to the drive carrier can occur if adjacent disk drives are removed at the same
time.
To maintain proper airflow and cooling inside the enclosure, install either a disk drive
or a blank drive carrier into the empty drive bay as quickly as possible.
If you will be installing a replacement disk drive, allow it to acclimate to room
temperature before continuing.