Technical Specifications
96-00290-001 Rev. A1 DataDirect Networks StorageScaler 2460 User Guide | 30
NOTE :
SS2460 enclosures do not support single APC configurations due to thermal
requirements.
NOTE :
In the event of a power supply failure, the blowers in the failed supply will
continue to operate on power provided by the redundant APC unit.
A.2 Regulatory Compliance Statements
Temperature
Operating: 5 °C to +40 °C
Storage: 1 °C to +60 °C
Transit: -40 °C to +60 °C
Maximum Rate of Temperature Change: 20 °C per hour
Humidity
Relative Humidity Operating: 20% to 80%, non-condensing
•Maximum Rate of Operational Humidity Change: 10% per hour
Relative Humidity Storage: 10% to 80%, non-condensing
Altitude
Altitude Operating: -200 to 10,000 feet
Altitude Storage: -200 to 10,000 feet
Operational Shock
5 G half sine shock with pulse duration of 11 milliseconds or less.
Non-Operational Shock
Half Sine Shock: 10 G half sine shock with pulse duration of 11 milliseconds or less.
Operational Vibration
Sinusoidal vibration from 5 to 500 Hz at 0.16 G (0 to peak) at a sweep rate of 0.5 octaves
per minute.
Random vibration from 5 to 500 Hz at 0.15 G (rms).
Non-Operational Vibration
Sinusoidal vibration from 5 to 500 Hz at 0.75 G (half-sine) at a sweep rate of 0.5 octaves
per minute.
Random vibration from 5 to 500 Hz at 0.5 G (rms).