Page view 84
| +--/\/\/\--+ |
| | |
8 RI <-|----+----------------+--o on battery | 2 Black
| | |
9 CTS <-|----+ |
| signal |
5 GND --|-----------------------o ground | 7 Red
| |
3 TxD | |
| chassis |
Chassis/GND |-----------------------o ground | 4 Black
| |
| Not connected | 1, 5, 6, 9, 10
--------------------------------------
The RJ45 pins are: looking at the end of the connector:
10 9 8 7 6 5 4 3 2 1
_______________________
| . . . . . . . . . . |
| |
-----------------------
|____|
940-0128D Cable Wiring
Supported
Models:
BackUPS XS1000(BX-1000), Possibly other USB models
Contributed
by:
Jan Babinski jbabinsk at pulsarbeacon dot com
940-0128D is functionally similar to the 940-0128A cable except for NC on (6) DTR and (2) RD on the
computer side.
Unverified: Try setting apcupsd to UPSTYPE dumb and UPSCABLE 940-0128A.
APC Part# - 940-0128D
DB9(Computer) RJ45-10(UPS)
(5) (1) ____________
( o o o o o ) [ oooooooooo ]
\ o o o o / [____________]
(9) (6) (10) [_] (1)
RI(9)<---+
|
CTS(8)<---+--- E 2N2222(NPN)
\|___
____ /| B |
| C |
| |
+---vvvv---+--[>|------<(2)OnBatt
RTS(7)>---| 2k 1N5819
Page view 84