the web interface of devices that use basic authentication without being prompted for
credentials.
Note: You cannot automatically login to the web interfaces of APC SNMP devices
monitored by NetBotz Appliance versions 320, 420, and 500.
Element Description
HTTP
Click to select the HTTP protocol for browser
communication.
HTTPS
Click to select the security-enhanced HTTPS
protocol for browser communication.
Port
Identify the number of the port used for browser
communication at a selected device: 80 is the
default for HTTP; 443 is the default for
HTTPS.
Username
Identify the username used to login to the device.
Password
Identify the password used to login to the device.
"Outlet Control" display
Use this display to control the outlets on the supported APC or third-party Rack PDU device.
You must specify the write community name for the Rack PDU device at device discovery,
or in the "Edit Device Scan Settings" display, accessed from the Device Scan Settings
option of the SNMP Device Communication Settings option in the Device menu.
You can configure delay parameters for the outlets via SNMP or by logging into the device.
A "Communication Error" is displayed when the Rack PDU device does not respond to a
command for any reason, for example, when the write community name identified in the
"Device Scan Settings" display is incorrect.
User permissions defined in the "Modify Device Group Access" display, accessed from
the Users and User Groups option in the System menu, determine which users have
access to outlet control. StruxureWare Central Server Administrators, Device
Administrators, and Device Viewer users with monitoring access set for Administration
Access or View and Control can access outlet control.
CAUTION: When you perform a command at an outlet that is part of an outlet group, that
command will be executed at all outlets in the group. The StruxureWare Central server
cannot determine which outlets are part of an outlet group.
Element Description
List
Name: Select one or more outlets to control.
Status: The status of the outlet.
Command
Select the command you wish to perform at the
selected outlets.
Note: Only the commands supported by the
selected device are listed.
Refresh Status
Click to update the status of the outlets.
Perform Command
Click to perform the command at the outlets
selected.
StruxureWare Central 6.3.0
46