Table 16-4 freewatt PLUS System Fuses
Location QTY Amp Voltage Spares Shape Size
Control Module (Control board, GDB Fuse) 1 2 250 0 Cylinder 5mm X 20mm
Boiler (Control Board F1, Lower RH Corner) 1 5 250 2 Cylinder 5mm X 20mm
Boiler (Control Board F3, Middle Right Side) 1 4 250 2 Cylinder 5mm X 20mm
MCHP* 1 1 650DC 0 Cylinder 6.35mm x 32mm
MCHP * 2 20 600AC 0 Cylinder 10.3mm x 38.1mm
APC UTS6H Control Board
(Use Littlefuse KLKR15 or eqiv.)
6 15 600AC
0
Cylinder 10.3mm x 38.1mm
* Refer to MCHP Shop Manual
16 - TROUBLESHOOTING
16.6 freewatt
PLUS System Fuses
WARNING
Label all wiring prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Disconnect power to system
before servicing. Failure to comply could result in
severe personal injury or death.
!
WARNING
Do not jumper fuse. Replace speci ed as listed.
Failure to comply could result in severe personal
injury, or death.
!
NOTICE
Check control module fuses before replacing control
module or other major component (pump, motor,
etc.). Blown fuse may prevent system control
module or other components from operating.
NOTICE
On board fuses are not available from ECR
International. Service technicians should provide
fuses for
freewatt
PLUS service from local suppliers.
Refer to Table 16-4.