Apc SGI 15000 RAID User Manual Page 104

  • Download
  • Add to my manuals
  • Print
  • Page
    / 152
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 103
90 007-5510-002
4. Remove the module’s thumbscrews, then slide the module out of the bay.
5. Slide the module into the bay making sure it is fully inserted. Install the two thumbscrews to secure
it.
6. Turn on the power switch. Check that the Status LED is green, indicating that the module is
operating normally.
7. Replace the cover panel (if necessary).
4.2.1.2 Fan Failure
A fan failure error message will display on your console if the fan module fails. Follow these steps to
replace the module.
NOTE :
The controller should not be operated without the fan module for more than 15 seconds. Make
sure you have the replacement fan unit available before removing the failed fan unit.
1. If a cover panel has been installed, take it off by removing its two thumbscrews.
2. Remove the two thumbscrews from the fan module
(Figure 4–5).
3. Slide the module out of its bay.
Figure 4–5 Fan Module
4. Slide the new module into the bay, making sure it is fully inserted.
5. Install the thumbscrews to secure it.
6. Replace the cover panel (if necessary).
4.2.2 Recovering from Drive Failures
When a drive failure occurs on the controller, the tier containing that drive will begin operating in
degraded mode. This means that the tier will continue to handle I/O commands from the host, but there
will be no redundancy to protect against additional drive failures on the same tier. If another disk drive
fails on the same tier before the data on the first drive is rebuilt (to a replacement disk or hot spare), the
tier will go offline.
If one disk in a tier fails, the data or parity information on the failed disk will be reconstructed from the
parity disk and data disks of that tier. An entire channel may fail without data loss.
It is recommended that the controllers Automatic Disk Rebuild function be enabled at all times (TIER
AUTOREBUILD=ON).
Thumbscrew
Thumbscrew
Page view 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 151 152

Comments to this Manuals

No comments